17.
START-UP
•To remove the protective cover of the SDM control unit,
delicately obtain leverage with a screwdriver as shown in fig.
41.
•To refit it, attach it on the top part and press as shown in fig.
42.
•To remove the motor unit's cover, loosen the screws.
•Manually check correct movement of the leaves and all
moving elements.
•Make/check all electrical connections on the SDM board of
the power cables from the toroidal transformer, from the motor
and from all accessories - routing the cables inside the pre-
fitted cable sleeves.
•Set motor direction of rotation according to type of door
(refer to the instructions of the SDM board).
•Check if a jumper is present on terminal board J7 of the SDM
board (refer to the SDM board).
•Connect the 230V power cables to the terminals inside the
motor unit (fig. 43 ref.
).
Note: a 1A time-delay fuse is also supplied to protect the
transformer.
•Set automatic operating mode and execute setup.
•Check the efficiency of all installed accessories, especially
photocells and sensors.