Battery card installation procedure:
•cut mains power;
•insert the battery card in connector J11, J12 or J13 of the
940SDM control board;
•restore mains power;
•using the SD-Display, activate the “Battery Kit” and
set the required operating parameters (the standard
configuration is described further below);
•connect the batteries to the battery card on connector J2.
IMPORTANT: TO AVOID DAMAGING THE BATTERY CARD:
•ALWAYS insert and remove the battery card while mains power
is OFF.
•connect the batteries (connector J2) only when the battery
card has already been inserted.
OUT2
OUT1
LD2
LD1
F1
J2
J3
J1
F1
Fuse 20 T5A/250V (battery protection)
J1
Connection to 940SDM control board
J2
Battery connection
J3
Not used
OUT 1
Relay output (Com/NC/NO)
OUT 2
Relay output (Com/NC/NO)
LD1 (green)
Door power supply mode
LD2 (red)
Battery charge status
(1) If the red LED does not start to flash within about 30 mins,
the causes may be as follows:
- incorrect battery connection or no battery connection;
- fuse F1 interrupted;
- batteries or battery card damaged.
By using the SD-Display, you can select door behaviour
in battery operation mode, so that, if mains power fails:
OPERATING FUNCT. other than NIGHT and STANDARD BAT.
OPERATION programming:
•the control board continues to operate normally until the
battery has only sufficient reserve charge to perform at least
one emergency movement, after which
•the last programmed movement is performed (opening or
closing), and finally
•the 940SDM control board goes into ENERGY SAVING status.
OPERATING FUNCT. other than NIGHT and NO STANDARD BAT.
OPERATION programming:
•the last programmed movement is immediately performed
(opening or closing), after which
•the 940SDM control board goes into ENERGY SAVING status.
NIGHT OPERATING FUNCT. and NIGHT STANDARD BAT.
OPERATION programming:
•the 940SDM control board goes into NIGHT ENERGY SAVING
status.
NIGHT OPERATING FUNCT. and NIGHT NO STANDARD BAT.
OPERATION programming:
•the control board continues to operate normally until the
battery has only sufficient reserve charge to perform at least
one emergency movement, after which
•the 940SDM control board goes into NIGHT ENERGY SAVING
status.
ENERGY SAVING (other than Night operating function)
•+VAC is switched OFF;
•SD-Keeper shows ENERGY SAV. on the Display, the alarm is
signalled, back lighting goes OFF, menus cannot be scrolled,
and only the keys for changing the operating function remain
active.
NIGHT ENERGY SAVING (Night operating function)
•+VAC is switched OFF;
•SD-Keeper completely OFF.
These statuses can be exited in the following ways:
WAKE-UP PROCEDURE (KEY INPUT FOR 3 SEC)
If the last selected movement was opening, the SD-Keeper re-
activates itself for night pause time and then returns to
ENERGY SAVING status.
If the last selected movement was closing, opening is executed.
When the door is open, the SD-Keeper re-activates itself for
night pause time, after which the +Vacc is re-activated too
(to allow the photocells to operate) and the door re-closes
(SD-Keeper resumes its ENERGY SAVING status).
BY ACTIVATING AN EMERGENCY INPUT (EMERG1 or EMERG2)
Providing it was set, the emergency movement is executed.
SD-Keeper stays ON during the period when the emergency
status remains active. Vacc is re-activated if a closing
movement is requested.
BY USING THE LOCK KNOB
See the WAKE-UP function.
NOTE: by using SD-Display, you can configure lock
operation in battery-powered Night mode.
- the door is mains powered
- battery at very low charge level (1)
- OUT1 not active
- OUT2 active
- the door is mains powered
- battery now recharging; if mains power fails, no
emergency movement is guaranteed (2)
- OUT1 not active
- OUT2 active
- the door is mains powered
- the battery is charged; if mains power fails, door
movement is guaranteed
- OUT1 active
- OUT2 active
- the door is battery-powered
- battery fully discharged (3)
- OUT1 not active
- OUT2 not active
- the door is battery-powered
- battery now discharging; at least one emergency
movement is guaranteed (2)
- OUT1 not active
- OUT2 not active
- the door is battery-powered
- the battery is charged and can move the door
- OUT1 active
- OUT2 not active
GREEN LED ON
RED LED OFF
LED RED
ON
LED RED
FLASHING
LED RED
OFF
(2) recharging time for fully discharged batteries: about 14
hours.
(3) No emergency movement is possible: the accessories
connected to +Vacc and SD-Keeper are turned OFF and the
Manual operating mode is set.
Содержание 940SMT
Страница 5: ...4 ENGLISH ENGLISH 25 21 4 164 5 205 40 5 79 5 71 5 179 5 14 6 10 15 15 50 251 195 Fig 2...
Страница 11: ...10 ENGLISH ENGLISH 36 36 200 12 18 HA 165 LH max 2500 14 6 10 5 INSTALLATION HA LH 15 4 mm 10 Fig 7...
Страница 12: ...11 ENGLISH ENGLISH HA LH 15 4 mm 10 Fig 8 14 6 10 LH max 2500 12 18 135 HA 200...