32
ENGLISH
ENGLISH
11111 LANGUAGE
LANGUAGE
LANGUAGE
LANGUAGE
LANGUAGE
Selects the language for showing the messages on the display.
22222 SETUP
SETUP
SETUP
SETUP
SETUP
2.1 P
2.1 P
2.1 P
2.1 P
2.1 PARTIAL OPENING
ARTIAL OPENING
ARTIAL OPENING
ARTIAL OPENING
ARTIAL OPENING
Partial opening percentage
Partial opening percentage
Partial opening percentage
Partial opening percentage
Partial opening percentage
Selects the opening percentage (referred to total opening)
performed in the “partial opening” operational function.
Standard value: 50%
Adjusting range: from10% to 90%
Standard
Standard
Standard
Standard
Standard
When the “partial opening” operational function is selected,
sensor activation always causes a partial opening command.
No Standard
No Standard
No Standard
No Standard
No Standard
When the “partial opening” operational function is selected,
simultaneous activation of the internal and external sensors
commands total opening.
2.2 P
2.2 P
2.2 P
2.2 P
2.2 PA
AA
AAUSE TIME
USE TIME
USE TIME
USE TIME
USE TIME
O n
O n
O n
O n
O n
Pause time enabled in the “automatic” operational function.
Pause time value
Pause time value
Pause time value
Pause time value
Pause time value
If pause time is enabled, it can be set.
Standard value: 2 sec.
Adjusting range: from 0 to 90 sec.
Off
Off
Off
Off
Off
The leaves begin the closing stage as soon as the command
elements (e.g. sensors) are inactive.
2.3 NIGHT P
2.3 NIGHT P
2.3 NIGHT P
2.3 NIGHT P
2.3 NIGHT PA
AA
AAUSE TIME
USE TIME
USE TIME
USE TIME
USE TIME
Night pause time value
Night pause time value
Night pause time value
Night pause time value
Night pause time value
Sets pause time in the “night” operational function.
Standard value: 3 sec.
Adjusting range: from 2 to 240 sec in steps of 2.
2.4 ANTI-INTRUDER
2.4 ANTI-INTRUDER
2.4 ANTI-INTRUDER
2.4 ANTI-INTRUDER
2.4 ANTI-INTRUDER
O n
O n
O n
O n
O n
In “Automatic” operating mode, the door opposes manual
opening attempts by means of contrary force.
During the attempt to open, an alarm is signalled on the control
board (“Error” LED flashing slowly) and on the SD-Keeper (alarm
#3 - forced door).
Off
Off
Off
Off
Off
In “automatic” operating mode, when manual opening is
attempted, the door opens automatically and re-closes after
any pause time.
Note: In the “night” operational function, the anti-intruder is
always active.
2.5 OBST
2.5 OBST
2.5 OBST
2.5 OBST
2.5 OBSTACLE DETECTION
ACLE DETECTION
ACLE DETECTION
ACLE DETECTION
ACLE DETECTION
Closing: Standard
Closing: Standard
Closing: Standard
Closing: Standard
Closing: Standard
If an obstacle is detected during closing, the door re-opens.
During the next closing operation, closing is decelerated at
the point where the obstacle had been detected, and
continues at the slower speed until completed.
Closing: No Standard
Closing: No Standard
Closing: No Standard
Closing: No Standard
Closing: No Standard
If an obstacle is detected for 3 consecutive times at closing,
the door stops in open position, and causes an alarm signal
on the control board (“error” LED) and on SD-Keeper (alarm
No.9 - obstacle during closing).
To restore operation, resetting is necessary either from the control
board or from SD-Keeper.
Opening: Standard
Opening: Standard
Opening: Standard
Opening: Standard
Opening: Standard
If an obstacle is detected during opening, the door stops for
one second and then re-closes.
During the next opening operation, opening is decelerated
at the point where the obstacle had been detected, and
continues at the slower speed until completed.
Opening: No Standard
Opening: No Standard
Opening: No Standard
Opening: No Standard
Opening: No Standard
If an obstacle is detected for 3 consecutive times at opening,
the door stops in closed position, and causes an alarm signal
on the control board (“error” LED) and on SD-Keeper (alarm
No.8 - obstacle during opening ).
To restore operation, resetting is necessary either from the control
board or from SD-Keeper.
33333 BA
BA
BA
BA
BATTTTTTERY
TERY
TERY
TERY
TERY
3.1 BA
3.1 BA
3.1 BA
3.1 BA
3.1 BATTTTTTERY KIT
TERY KIT
TERY KIT
TERY KIT
TERY KIT
Off
Off
Off
Off
Off
Battery kit not installed.
O n
O n
O n
O n
O n
Battery kit installed.
3.2 BA
3.2 BA
3.2 BA
3.2 BA
3.2 BATTTTT. OPERA
. OPERA
. OPERA
. OPERA
. OPERATION
TION
TION
TION
TION
Standard
Standard
Standard
Standard
Standard
If there is a power cut and the operating function is other than
“Night”, the door continues operating normally until the battery
has sufficient charge reser ve to perfor m at least one
emergency movement.
The last movement operation to be executed is the one
selected with function 3.3.
No Standard
No Standard
No Standard
No Standard
No Standard
In the event of a power cut, the door executes only the moving
operation selected with function 3.3.
3.3 LAST OPERA
3.3 LAST OPERA
3.3 LAST OPERA
3.3 LAST OPERA
3.3 LAST OPERATTTTT.....
Opening
Opening
Opening
Opening
Opening
During battery operated functioning, the last moving operation
is opening (see also function 3.2).
Closing
Closing
Closing
Closing
Closing
During battery operated functioning, the last moving operation
is closing (see also function 3.2).
3.4 NIGHT BA
3.4 NIGHT BA
3.4 NIGHT BA
3.4 NIGHT BA
3.4 NIGHT BATTTTTTTTTT.....
Standard
Standard
Standard
Standard
Standard
In the event of a power cut, and with the “Night” operating
function selected, the control board operates immediately in
low consumption mode; opening is possible only by activating
emergency opening, or the key command for 3 seconds (Key
input).
No Standard
No Standard
No Standard
No Standard
No Standard
In the event of a power cut and with the “Night” operating
function selected, the door operates normally until the battery
has sufficient charge reser ve to perfor m at least one
emergency movement.
4
44
44 LLLLLOCK
OCK
OCK
OCK
OCK
4.1 KIT L
4.1 KIT L
4.1 KIT L
4.1 KIT L
4.1 KIT LOCK
OCK
OCK
OCK
OCK
O n
O n
O n
O n
O n
Lock installed.
Night
Night
Night
Night
Night
The lock locks the leaves only in the “night” operational function.
One way + night
One way + night
One way + night
One way + night
One way + night
The lock locks the leaves in the “night” and “one way”
operational functions.
Always
Always
Always
Always
Always
The lock locks the leaves whenever they close, irrespective of
the set operational function.
Note: During battery operated functioning, the lock locks
the leaves only in “night” operational function,
irrespective of the set selection.
Off
Off
Off
Off
Off
Lock not installed.
4.2 NIGHT L
4.2 NIGHT L
4.2 NIGHT L
4.2 NIGHT L
4.2 NIGHT LOCK
OCK
OCK
OCK
OCK
Standard
Standard
Standard
Standard
Standard
In the “night” operational function, with discharged batteries,
the lock keeps the leaves locked.
No Standard
No Standard
No Standard
No Standard
No Standard
In the “night” operational function, the lock is released before
the batteries are fully discharged.
4.3 SURVEILLANCE
4.3 SURVEILLANCE
4.3 SURVEILLANCE
4.3 SURVEILLANCE
4.3 SURVEILLANCE
Off
Off
Off
Off
Off
Surveillance device on lock not installed.
O n
O n
O n
O n
O n
Surveillance device on lock installed.
Содержание 940SMT
Страница 5: ...4 ENGLISH ENGLISH 25 21 4 164 5 205 40 5 79 5 71 5 179 5 14 6 10 15 15 50 251 195 Fig 2...
Страница 11: ...10 ENGLISH ENGLISH 36 36 200 12 18 HA 165 LH max 2500 14 6 10 5 INSTALLATION HA LH 15 4 mm 10 Fig 7...
Страница 12: ...11 ENGLISH ENGLISH HA LH 15 4 mm 10 Fig 8 14 6 10 LH max 2500 12 18 135 HA 200...