SD-KEEPER PROGRAMMING UNIT
SD-KEEPER PROGRAMMING UNIT
SD-KEEPER PROGRAMMING UNIT
SD-KEEPER PROGRAMMING UNIT
SD-KEEPER PROGRAMMING UNIT
SD-Keeper is used for selecting operational functions, as
well as adjusting and programming the 940 SF series
automated doors.
It is divided into two parts: a fixed part used for selecting
the operating functions by means of push-buttons and
relevant signalling LEDs (fig.1 ref. A), and a pull-out part
with LCD display to access complete programming (fig.1
ref. B).
The SD-Keeper display can be used as a temporary
programming unit: after all programming and adjustments
have been carried out, it can be fully removed because
the settings remain stored on the 940SDM control board.
When the display is removed, a cover is provided (fig.1 ref.
C).
SD-Keeper can be disabled by a combination of keys (see
the special LOCK function) or by internally fitting a jumper
by means of a switch (fig.2 ref. LOCK).
FITTING
FITTING
FITTING
FITTING
FITTING
Refer to fig.2 for an exploded view of fitting. Let cable
route through point A or B according to the cable position
needs.
CONNECTIONS
CONNECTIONS
CONNECTIONS
CONNECTIONS
CONNECTIONS
Connect SD-Keeper to the 940SDM control board with
the following cable: 2x0.5mm
2
max 50m (fig. 2).
If a jumper is closed between two terminals as shown in
fig.2 (LOCK), all keys on the programmer are disabled.
DIAGNOSTICS
DIAGNOSTICS
DIAGNOSTICS
DIAGNOSTICS
DIAGNOSTICS
SD-Keeper (also without display) has a diagnostic function
which, in case of an alarm, interrupts normal display of the
function every 2 seconds in order to show the fault status
for 1 second by a combination of flashing LEDs.
Consult fig. 3 and table 1 to identify the type of alarm by
interpreting the flashing LEDs.
Â
If there are several simultaneous faults, the first to be
detected is shown.
fig. 3
햲
햳
햴
햵
햶
햷
햸
햹
Tab.1 DIAGNOSTICS
Led =on =off
DESCRIPTION
MEANING
ENERGY SAV.
Operating on low battery consumption
1 SPEED CHANGES Speed changed, new setup required
2 BAT. OPERATION Door operating on battery
3 FORCED OPEN
Door forced opening in progress.
4 FLAT BATTERY
Battery discharged: emergency movement not guaranteed
6 EMERG 2 ON
Emergency 2 input active
7 EMERG 1 ON
Emergency 1 input active
8 OBST. IN OPEN.
Opening obstacle detected 3 successive times; Reset necessary to restore operation.
9 OBST. IN CLOS.
Closing obstacle detected 3 successive times; Reset necessary to restore operation
10
콯
Lock locked in closed position
11
콯
Lock locked in open position (with surveillance kit only)
12
콯
Incorrect power supply to motor (VMOT absent)
13
콯
Photocell 2 faulty (PSW2 input)
14
콯
Photocell 1 faulty (PSW1 input)
15
콯
Setup not possible
18
콯
Initialisation process not possible on motor: leaf stroke too long
20
콯
Initialisation process not possible on motor: insufficient leaf stroke
22
콯
Initialisation process not possible on motor: too much friction or leaf too heavy
24
콯
Motor failure
25
콯
940SDM control board faulty
fig. 1
B
C
A
햲 햳 햴 햵 햶
햹
햸
햷
2x0.5 mm
2
max 50m
fig. 2
A
B
J6 SDM
13 12
LOCK