The first time the door is powered, the 940SDM control
board automatically executes a setup procedure and
loads all the standard configuration settings.
ST
ST
ST
ST
STANDARD CONFIGURA
ANDARD CONFIGURA
ANDARD CONFIGURA
ANDARD CONFIGURA
ANDARD CONFIGURATION
TION
TION
TION
TION
The standard configuration is as follows:
•“AUTOMATIC”-“TOTAL”-“TWO-WAY”; operating function;
•maximum OPENING SPEED (level 10);
•CLOSING SPEED level 3;
•EMERG1 emergency input configured as a “no memory”
NO contact, i.e. when activated, it causes the movement
to stop and the door remains open in stop status for as
long as the contact is maintained;
•EMERG2 emergency input configured as a “no memory”
NO contact, i.e. when activated, it causes opening at
normal speed and the door remains open for as long as
the contact is maintained;
•two photocells with NC contact are supplied, to be
connected to the PSW1 and PSW2 contacts (if one or
both are not installed, jumper connections must be made
according to the diagram);
•FAILSAFE disabled;
•ANTI-INTRUDER function active;
•PAUSE time 2 sec.;
•NIGHT PAUSE time 8 sec.;
•KIT LOCK enabled in standard mode (locks in NIGHT mode
only);
•SURVEILLANCE KIT on disabled lock;
•BATTERY KIT not enabled;
•OUT1 output with GONG function;
•OUT2 output with LIGHT function;
•OUT3 output with DOOR NOT CLOSE function;
•PARTIAL OPENING set at 50%;
•no anticipated DECELERATION during opening and
closing;
•Low DECELERATION SPEED;
•Standard OBSTACLE DETECTION: if an obstacle is
recognised at opening or closing, the door reverses and
continuously attempts to move until the obstacle is
removed, without generating an alarm signal;
•two SENSORS with NO contact are provided (one internal,
the other external);
•NO type KEY contact;
•INTERLOCK function not activated;
•ANTI-PANIC KIT WITH ELASTIC not enabled;
•TIMER not activated.
IMPORTANT:
The standard configuration, particularly for the set speed
levels, does not guarantee compliance with standards
prEN12650-1 and prEN12650-2, specified for doors
distributed and installed in the European Union.
PHOTOCELLS
PHOTOCELLS
PHOTOCELLS
PHOTOCELLS
PHOTOCELLS
The following configurations are possible:
-NO PHOTOCELL
•In the standard configuration, PSW1 and PSW2 inputs
must be jumper connected to the FAILSAFE terminal;
•for the SD-Display, as an alternative, the PSW1
and PSW2 inputs can be disabled, thus avoiding the
jumpers.
-1 PHOTOCELL
•In the standard configuration, the photocell must be
connected to the PSW1 input, while PSW2 must be jumper
connected to the FAILSAFE terminal;
•for the SD-Display, as an alternative, one
photocell only can be set (connecting it to the PSW1
input as usual), thus disabling the PSW2 input and avoiding
the jumper (see the SD-Keeper programming
instructions).
-2 PHOTOCELLS
•connect the photocells to the PSW1 and PSW2 inputs.
Programming with the SD-Display makes it possible
to (see programming instructions):
•select the number of connected photocells (2,1,0);
•select the type of contact (NO/NC) of the PSW1 and
PSW2 inputs;
•enable/disable the failsafe.
SETUP
SETUP
SETUP
SETUP
SETUP
The following parameters are checked and adjusted
during the Setup cycle:
•measurement of masses and friction, setting of speeds,
plus optimal acceleration and deceleration;
•acquisition of open and closed door positions;
•self-setting of the anti-crushing system at opening/closing
according to selected speeds.
During Setup, the ERROR LED flashes rapidly and goes off
at the end of the process if correctly executed.
Any faults are signalled by the ERROR LED and by the
diagnostics via SD-Keeper.
Detection of serious faults (e.g. insufficient or excessive
leaf travel, too much friction, motor malfunctions) causes
the ERROR LED to light up steadily.
Subsequent variations of closing speed (by the push-
buttons on the control board or SD-Display) are
signalled by a slowly flashing ERROR LED and by ALARM 1;
in this case, a new Setup is necessary to ensure that the
electronic anti-crushing device operates correctly.
To activate a new Setup procedure, press the SETUP push-
button on the control board; Setup can also be started by
a combination of push-buttons on SD-Keeper (see
relevant instructions).
The following are the situations in which, if required, the
Setup cycle is not executed, and the door stays in shut-
down state, generating an alarm signal (slowly flashing
ERROR LED and ALARM 15 on SD-Keeper):
•door powered by battery;
•NIGHT operating function selected;
•MANUAL operating function selected;
•DOOR OPEN operating function selected;
•an emergency input is active;
•photocells engaged;
•no power supplied to motor.
When the cause has been eliminated, the Setup starts
automatically.
RESET
RESET
RESET
RESET
RESET
Whenever the automated system is powered, the door
executes a Reset cycle during which:
•the door's travel limit positions are sought;
•any alarm signals are reset.
To activate a new Reset procedure, press the RESET push-
button on the control board; Reset can also be started by
a combination of push-buttons on SD-Keeper (see
relevant instructions).
If a Reset is commanded while the door is in “Manual”
mode, it is executed when this operating function is exited.
In the “Night” operating function, Reset consists of a slow
closing movement, whereas it is normally a slow opening
movement.
During Reset, the ERROR LED flashes rapidly.