IN1608 xi Scaling Presentation Switcher • SIS Configuration and Control
76
Command
ASCII Command
(Host to Scaler)
Response
(Scaler to Host)
Additional Description
Ethernet to RS-232 Insertion (continued)
Ethernet Data Port
Set current connection port
timeout
24
E
0*
X6^
TC
}
Pti0*
X6^]
Set the number of seconds before
the current port timeout to
X6^
.
View current connection
port timeout
E
0TC
}
X6^]
In verbose modes 2 and 3:
Pti0*
X6^]
View the current port timeout setting
(
X6^
).
NOTE:
The Set and View current connection port timeout commands are available only with an Ethernet connection.
Set global IP port timeout
24
E
1*
X6^
TC
}
Pti0*
X6^]
Set the number of seconds before
all ports time out to
X6^
.
View global IP port timeout
E
1TC
}
X6^]
In verbose modes 2 and 3:
Pti1*
X6^]
View the global port timeout setting
(
X6^
).
Set UART start point
EX6&
MD
}
Pmd
X6&]
Set current UART starting port to
X6&
.
View UART start point
E
MD
}
X6&]
In verbose modes 2 and 3:
PtiO*
X6&]
View the UART starting port number
(
X6&
).
NOTES:
X6^
= Port timeout
Set in increments of 10 seconds:
1
(10 seconds) to
65000
(650,000 seconds)
Default =
30
(300 seconds)
X6&
= Start point for UART ports
Controller RS-232 = port 1024
Port number range =
1024-65533