Group controls
When grouped, gain control members move together at relative levels. If one member
reaches its limit, it retains that position while the other members continue to travel. When the
grouped members travel in the reverse direction, the member that was at its limit reverts to
its position relative to the other members.
When grouped, mute control members update to indicate they are part of a group. Group
members can be individually muted as well. When grouped members are individually muted,
they are exempt from the setting of the group master.
The
Audio
Configuration
page has an output volume
Group
Controls
fader, which is
displayed to the right of each of the four audio configuration tabs. Figure 76,
1
, shows the
fader displayed next to the
Line
Input
screen.
Figure 76.
Group Controls Fader Beside Line Input Page
Use the
Group
Controls
fader to adjust and set the volume level of all outputs at once.
The fader contains high and low master controls that let you set your own maximum and
minimum limits for the fader.
To adjust the volume using the Group Controls fader, do any of the following:
•
Click and drag the handle of the audio level fader of the corresponding output.
•
Click the
Up
and
Down
arrows in the field below the corresponding output.
•
Enter a value in the text field below the fader.
Below the fader is a
Mute
button (
2
). Clicking this button mutes all audio signals. When
you click this button, it turns red, like the
Audio
Mute
button in the