IN1608 xi Scaling Presentation Switcher • SIS Configuration and Control
49
SIS Overview
Using the Command and Response Table
for SIS commands beginning on page 56 lists
the commands that the scaler recognizes as valid, the responses that are returned to the
host, a description of the command function or the results of executing the command, and
examples of commands in ASCII (Telnet).
NOTE:
Unless otherwise stated, the commands are not case-sensitive.
ASCII to Hex Conversion Table
•
Space
Figure 36.
ASCII to Hexadecimal Character Conversion Table
Symbol Definitions
•
= Space
]
= Carriage return with line feed
}
= Carriage return with no line feed
|
= Pipe (vertical bar) character
E
or
W
= Escape key
14, 24, 28
= Superscripts indicate the error message displayed if the command is entered
incorrectly or with invalid parameters (see
on the
previous page).
X!
= Input selection
1-8
X@
= Output selection
1
= Output 1A – HDMI (top connector)
2
= Output 1B – HDMI (bottom connector)
3
= Output 1C – DTP/HDBT
X#
= Input video format
1
= RGB (default for inputs 1 and 2)
2
= YUV
3
= RGBcvS
4
= S-video
5
= Composite
6
= HDMI (default for inputs 3 and higher)
Options
3
-
5
are valid for inputs 1 and 2 only.
X$
= Horizontal or vertical start
0-255
(default midpoint of 128 translates to the
default value in the input lookup tables)
X%
= Pixel phase
0-63
(
31
= default)
X^
= Total pixels
±
512
of the default value
X&
= Active pixels
±
512
of the default value
X*
= Active lines
±
256
of the default value