IN1608 xi Scaling Presentation Switcher • SIS Configuration and Control
55
X6!
= Port number
1
= remote port (3-pole captive screw)
7
= UART** on DTP input 7
8
= UART on DTP input 8
9
= UART on DTP/HDBT output 1C
**UART = universal asynchronous receiver-
transmitter
X6@
= Baud rate
300
,
600
,
1200
,
1800
,
2400
,
3600
,
4800
,
7200
,
9600
(default),
14400
,
19200
,
28800
,
38400
,
57600
,
115200
NOTE:
Via PCS and the web pages, only
9600
,
19200
,
38400
, and
115200
baud
rates are selectable.
X6#
= Parity
Odd, Even, None, Mark, Space
(Only the first letter is required.)
X6$
= Data bits
7
or
8
(default)
X6%
= Stop bits
1
(default) or
2
X6^
= Port timeout
Set in increments of 10 seconds:
1
(10 seconds) to
65000
(650,000 seconds)
Default =
30
(300 seconds)
X6&
= Start point for UART ports
Controller RS-232 = port 1024
X6*
= Twisted pair (TP) format
0
= DTP format (Includes 12 VDC DTP remote
power, default)
1
= HDBaseT format
X6(
= DTP RS-232 insertion mode
0
= RS-232 pass-through – rear panel captive
screw connector (default)
1
= IP insert via UART