Slot for T1/E1 module with 16 ports
•
Grounding lug
•
Redundant DC input power connectors
Figure 2: E4G-200 Cell Site Router Front Panel
1 = Alarms connection (inactive)
5 = Slot for E4G-200 CLK module
2 = Management and console ports
6 = Slot for F16T1E1 module
3 = RJ-45 dedicated ports
7 = Grounding lug
4 = SFP ports
8 = DC input power connectors
The E4G-200 router has an integrated DC power supply with dual feeds on the front panel. Power feed
A can be connected to one power source and power feed B can be connected to a different power
source to provide protection should either source of power fail. The power supply is not field-
replaceable.
The back panel of the E4G-200 router provides an alternate attachment point for the grounding lug.
Status LEDs on the E4G-200 router are described in
Table 3: System LEDs
on page 13.
E4G-200 Power Supply
The E4G-200 router has an integrated DC power supply with dual feeds on the front panel. Power feed
A can be connected to one power source and power feed B can be connected to a different power
source to provide protection should either source of power fail. The power supply is not field-
replaceable.
The back panel of the E4G-200 router provides an alternate attachment point for the grounding lug.
E4G-200 Clock (CLK) Module
An optional clock module for the E4G-200 router provides timing. Timing is based on either:
•
ITU-T Synchronous Ethernet (SyncE) protocol
•
Precision Time Protocol based on the IEEE specification 1588v2
The clock module has four mini-BNC connectors providing Sync In/Sync Out timing interfaces and an
RJ-45 connector that provides an RS-422 BITS-IN interface. Clock modules can be installed or removed
without powering down the router, although a system reboot is required to initialize the module.
Extreme Networks E4G Series Routers
E4G Routers Hardware Installation Guide
11