background image

ENGLISH

1.

 Extraflame S.p.A. products are guaranteed, within the European community, for 24 months from the date of purchase. 

Purchase has to be proved by means of a valid fiscal document issued by the seller (receipt, invoice or shipment document) identifying the 

purchased product and its purchase and/or delivery date. 

Warning: This conventional guarantee does not replace the guarantee regulated by the European legislation on consumer rights.

The conventional guarantee is only applicable to the Italian region and to those areas, within the European Community, where the Authorised 

Technical Assistance Centres are active (see the www.lanordica-extraflame.com website)

It is also limited to the state of residence of the consumer, which must coincide with the premises and/or registered office of the seller of the 

Extraflame S.p.A. product 

These regulations do not apply if the product is purchased within commercial, entrepreneurial, or professional circumstances. In these cases 

the product guarantee will be limited to a period of 12 months from the date of purchase. 

ITALIAN GUARANTEE

What must be done if there is a product malfunction: 

Consult the instructions manual to make sure the malfunction cannot be solved by using the product correctly.  Make sure the malfunction is 

included in those covered by the guarantee; otherwise the cost of the intervention will be borne entirely by the consumer. When requesting 

the intervention of the Assistance service at the Authorised Assistance Centre, always specify: - type of malfunction - model of the appliance 

- complete address - phone number

EUROPEAN GUARANTEE

What must be done if there is a product malfunction: 

Consult the instructions manual to make sure the malfunction cannot be solved by using the product correctly. Make sure the malfunction 

is included in those covered by the guarantee; otherwise the cost of the intervention will be borne entirely by the consumer. Request the 

intervention of the Assistance service or the address of the Authorised Technical Assistance Centre to the seller; always specify: type of 

malfunction, model of the appliance, complete address and phone number

if the malfunction arises in the first 6 months of the product's life, the consumer has the right to have the product repaired with no expense. 

From the seventh to the twenty-fourth month, if a malfunction arises, the consumer will bear the cost of the call, while the seller will pay for the 

manpower and for any spare parts used.

2.

 If the malfunction is linked to external events and/or conditions such as, including but not limited to, insufficient capacity of the systems; 

wrong installation and/or maintenance by the personnel which hasn't got the skills prescribed by the laws of the country of residence of 

the consumer; negligence; inability to use the product and wrong maintenance by the consumer, with respect to what is reported and 

recommended by the instructions manual of the product, which is part of the sales contract, this guarantee will be void. 

Damage to the product that cannot be related to manufacturing defects are also not included in this guarantee. Similarly are excluded defects 

related to incorrect operation of the flue, according to the legislation in force in the country at the moment of purchase. Other exclusions 

include all product defects due to carelessness, accidental breakdown, tampering and/or damage during transport (scratches, dents, etc.), 

interventions carried out by unauthorised personnel and further damage caused by incorrect interventions by the consumer trying to arrange 

the initial malfunction. 

The following consumables are excluded by the guarantee: gaskets, ceramic or tempered glasses, cast iron grilles or coatings, refractory 

materials (e.g. Nordiker or others), painted, chrome-plated or golden parts, majolica ware, handles, the brazier and its related components. 

For Idro products the heat exchanger is not covered by the guarantee if a suitable condensation-proof circuit is not set up to ensure a return 

temperature of the device of at least 55°C. The guarantee excludes all the external components on which the consumer can directly operate 

during use and/or maintenance or that can be subject to wear and/or rust and stains on steel due to aggressive detergents. 

If malfunctions are signalled which are not later confirmed during check by an authorised technician, the cost of the intervention will be borne 

entirely by the consumer.

3.

 If it is not possible to restore product conformity by repairing it, the product/component will be replaced, the guarantee expiration date and 

conditions will remain the same established when the product/component to be replaced has been purchased.

4.

 Extraflame S.p.A. cannot be held liable for injury or damage which may - either directly or indirectly - be caused to persons, animals 

and property ensuing from failure to observe all the instructions provided in the relevant instruction manual and the warnings regarding 

installation, use and maintenance of the product, that can also be downloaded on the website.

5.

 Interventions for adjusting and/or regulating the product for the type of fuel or other reasons are excluded by the guarantee.

6.

 If the product is repaired in one of the Authorised Technical Assistance Centres indicated by Extraflame S.p.A. and if the product is replaced, 

transport will be free of charge. If the technician can repair the product at the user's place of residence and they refuse, transport to the 

workshop and redelivery will be paid by the consumer.

7.

 

After the 24 months of the guarantee have elapsed any repair intervention cost will be completely borne by the consumer.

8.

 In the case of disputes the only competent court is that of the Extraflame S.p.A. registered office - (Vicenza-Italy) 

GUARANTEE TERMS 

36

Содержание 001282600

Страница 1: ...MADE IN ITALY design production VIRNA IDRO 004276851 rev 002 UK THERMO PRODUCTS USER MANUAL...

Страница 2: ...ENGLISH 2...

Страница 3: ...hermostat 21 Additional thermostat functioning with STAND BY active 21 Additional thermostat operation with STAND BY deactivated 21 Additional thermostat installation 21 easy setup 22 CHRONO 22 Enabli...

Страница 4: ...IMP RATIF Avant de d placer le po le retirer le rev tement indiqu pour viter tout dommage ACHTUNG PFLICHT Bevor der Ofen bewegt wird muss die angezeigte Verkleidung entfernt werden um Sch den zu verme...

Страница 5: ...ITH REDUCED PHYSICAL SENSORY OR MENTAL CAPACITIES OR WITHOUT EXPERIENCE OR THE NECESSARY KNOWLEDGE PROVIDED THAT THEY ARE SUPERVISED OR HAVE RECEIVED INSTRUCTIONS ON SAFE USE OF THE APPLIANCE AND THAT...

Страница 6: ...r ignition During the filling phase do not put the bag of pellets to into contact with the product The majolicas aretop quality artisan products and as such can have micro dots crackles and chromatic...

Страница 7: ...at the documentation has been provided and must keep it with a copy of the technical documentation relating to the installation For installation in a condominium prior approval from the condominium s...

Страница 8: ...lection cap must be provided at the base of the vertical section If the exhaust is not inserted in an existing flue a vertical section with a windproof end piece is required UNI 10683 The vertical duc...

Страница 9: ...for passive houses because it does not take air in from within the house combustion air To ensure the stove remains hermetically sealed the connection pipe for the combustion air must be directly con...

Страница 10: ...and inspection of correct functioning must be carried out perfectly in full compliance with Standards in force national regional and municipal as well as these instructions For Italy installation mus...

Страница 11: ...harge into the flue This is to prevent unexpected power increases The flue fitting can be mounted between the boiler and the flue only after this inspection An inspection of the connections with pre e...

Страница 12: ...output T3 Boiler return input Virna IDRO details Combustive air rear inlet Lower fumes exhaust Upper fumes exhaust Combustive air side inlet Pellet hopper pressurised closure Heat exchanger scrapers E...

Страница 13: ...conveying motor and therefore operation of the heat generator The system must be bled several times to eliminate the air and loaded when the pressure is too low It is not an anomaly but normal phenome...

Страница 14: ...gnitionthestovewillgointo DEPRALARM mode while during normal operation the stove will go into COOLING WAITING TIME mode and then re start automatically when the correct conditions are present stove co...

Страница 15: ...be seasoned in order to obtain a sufficiently adequate heat yield THE USE OF POOR QUALITY PELLETS OR ANY OTHER MATERIAL DAMAGES THE FUNCTIONS OF THE GENERATOR AND CAN VOID THE WARRANTY AND THE ANNEXED...

Страница 16: ...external additional thermostat is closed and the STAND BY function is enabled Flashing with contact open the contact of the external additional thermostat is open and the STAND BY function is enabled...

Страница 17: ...must be followed the first times the stove is ignited It is possible that slight odours are produced due to the drying of the paints and silicone used Do not remain in the room for long periods Do not...

Страница 18: ...15 Decrease Decreases the value displayed 16 Stove status Displays the general status of the stove Battery type and replacement The battery is housed in the lower part of the remote control To replac...

Страница 19: ...d key 1 to return to the previous menus to the initial state Language This menu allows the preferred language to be selected The languages available are Italiano English German French Spanish Portugue...

Страница 20: ...d the stove will re start automatically and continue the working phase returning to the selected power level MODULATION and H OFF As the water temperature approaches the set point the boiler starts to...

Страница 21: ...inside the stove and relative factory setting restrictions If the stove is in H OFF water temperature reached any additional contact or thermostat request will be ignored Additional thermostat operati...

Страница 22: ...ENOUGH Controls procedure Press key 6 Press key 3 until easy setup appears and confirm by pressing key 6 Use keys 4 and 5 to set the range Press key 6 to confirm and key 1 to return to the previous m...

Страница 23: ...FF 00 00 PRG1 stop time Monday Sunday On off Enabling disabling days for PRG1 Set prg1 65 C 80 C 149 F 176 F Set thermostat PRG1 Power prg1 1 5 Set power PRG1 prg2 Start prg2 OFF 00 00 PRG2 start time...

Страница 24: ...02 00 23 00 08 00 16 30 t 02 00 23 00 08 00 16 30 t 3 1 02 00 23 00 08 00 16 30 t 72 68 2 1 Time slot 1 start 02 00 stop 23 00 power 3 set temp 72 C Time slot 2 start 08 00 stop 16 30 power 1 set tem...

Страница 25: ...via an additional thermostat Controls procedure Press key 6 Press key 3 until SETTINGS appears and confirm by pressing key 6 Continue by pressing key 3 until STAND BY appears and confirm by pressing k...

Страница 26: ...Press 3 until SETTINGS appears and confirm by pressing 6 Press key 3 until OUTLET AIR appears and confirm by pressing key 6 Use keys 4 and 5 for enabling ON or disabling OFF Press key one several time...

Страница 27: ...use abrasive or chemically aggressive detergents for cleaning The ceramic glass must be cleaned when the glass is completely cold To clean the ceramic glass simply use a dry brush and some damp newspa...

Страница 28: ...burn pot using the poker supplied Re position the burn pot in its seat and push it towards the fire wall Replace the pellet chute assembly on the burn pot Make sure that the burn pot and pellet chute...

Страница 29: ...ENGLISH EVERY 30 DAYS Cleaning the combustion chamber deflector Remove the deflector and eliminate the ash deposited in the upper part of the deflector 29...

Страница 30: ...physically and a pellet chute assembly B When cleaning and removing the burn pot remove the pellet chute assembly B by lifting it see figure Perform the same operation in reverse order to re assemble...

Страница 31: ...product warranty GASKETS pellet hopper lid DOOR ASH DRAWER AND BURN POT The gaskets guarantee the tightness of the stove and its consequent good functioning They must be controlled periodically They m...

Страница 32: ...let hopper ash drawer and door replace them and apply silicone where envisioned C Combustion chamber and heat exchanger full cleaning including ignition plug pipe D Hopper complete emptying and cleani...

Страница 33: ...llet hopper ash drawer and door replace them and apply silicone where envisioned C Combustion chamber and heat exchanger full cleaning including ignition plug pipe D Hopper complete emptying and clean...

Страница 34: ...it will re start automatically Anti freeze The anti freeze function is in progress as the H2O temperature is below the factory set threshold the pump is active until the water reaches the pre set fact...

Страница 35: ...tre MAX H20 PRESSURE ALARM Air in the system Inadequate circulation Possible air in the system bleed the system Lack of adequate circulation Lack of or inadequate safety zone The water in the stove ha...

Страница 36: ...ity to use the product and wrong maintenance by the consumer with respect to what is reported and recommended by the instructions manual of the product which is part of the sales contract this guarant...

Страница 37: ...t pipes etc Please therefore avoid coming into contact with these parts without wearing suitable protective clothing or using appropriate measures such as heat protective gloves DO NOT use the product...

Страница 38: ...ENGLISH 38...

Страница 39: ...ENGLISH 39...

Страница 40: ...lame it www lanordica extraflame com TO FIND THE SERVICE CENTRE NEAREST TO YOU CONTACT YOUR DEALER OR CONSULT THE SITE WWW LANORDICA EXTRAFLAME COM The manufacturer reserves the right to vary the char...

Отзывы: