1
2
3
4
5
6
OFF
ENGLISH
1
2
3
4
5
6
OFF
Control Board
ON/OFF BUTTON
ViewiNg OF VariOUs
TexT messages
TO aCCess
THe meNU
seTTiNgs
TemPeraTUre
aDJUsTmeNT
wOrKiNg
TemPeraTUre
display iCons key
indicates radio signal reception
Led off: radio communication not available.
Led on: radio communication available.
Flashing = serial port excluded
indicates modulation of the stove
Led on: the stove is working at the set power
Flashing: The power at which the stove is working differs from the
set power, the stove is modulating (for various reasons)
indicates the presence of an alarm.
Off: indicates there are no alarms
On: indicates the presence of an alarm.
Flashing: indicates the deactivation of the depression sensor.
indicates the weekly programming status
Off: deactivated
On: activated
indicates the water temperature status
Off= the T° read by the probe is higher than the set temperature
On= the T° read by the probe is lower than the set temperature
indicates contact of the external additional thermostat
Contact closed on = the contact of the external additional
thermostat is closed.
Contact open on: the contact of the external additional thermostat
is open.
Flashing with contact closed: the contact of the external additional
thermostat is closed and the sTaND-BY function is enabled
Flashing with contact open: the contact of the external additional
thermostat is open and the sTaND-BY function is enabled
indicates the status of the flue exhaust motor.
Off = motor deactivated
On = motor activated
Flashing = fault
indicates the summer/winter function
Off: The winter function is activated
On: the summer function is activated
Not in use.
indicates a request for DHw.
Off: DHw supplied, pump off
Flashing: a request for DHw exists, but the operating conditions
have not been met. Pump off
On: the request for DHw is in progress and the operating conditions
have been met. Pump on
indicates the status of the pellet loading motor.
Off = motor deactivated
On = motor activated
indicates a request for heating
Off: DHw supplied, pump off
Flashing: a request for heating exists, but the operating conditions
have not been met. Pump off
On: the request for heating is in progress and the operating
conditions have been met. Pump on
it indicates pump operation
Off = pump deactivated
On = pump activated
Flashing = the safety device is active (H2O temperature > 85°C)
indicates a buffer tank request, if active
Off: buffer tank request met, pump off
Flashing: a buffer tank request exists, but the operating conditions
have not been met. Pump off
On: the buffer tank request is in progress and the operating
conditions have been met. Pump on
16
Содержание 001282600
Страница 1: ...MADE IN ITALY design production VIRNA IDRO 004276851 rev 002 UK THERMO PRODUCTS USER MANUAL...
Страница 2: ...ENGLISH 2...
Страница 38: ...ENGLISH 38...
Страница 39: ...ENGLISH 39...