ENGLISH
note for correct operation
Pellet hopper lid
fire door
The following indications must be respected for correct pellet
stove operation:
During stove operation, the pellet hopper lid and the door must
always be closed.
failure to comply with the above during operation will cause the
display to show the following:
“closE hoppEr - sTovE Door"
This indication means that you have 60" to close the hatch/door
and the pellet lid.
If not, during ignition the stove will go into "
DEpr alarm"
mode,
while during normal operation the stove will go into "
cooling
- WaiTing TimE"
mode and then re-start automatically when
the correct conditions are present (stove cold, etc.).
stoVe positioning
To ensure the stove works correctly, it should always be positioned so that it is perfectly level, using a spirit level.
rearm
The figure below shows the rearm position (95°C). A qualified
technician should be contacted if the rearm is triggered to verify the
cause.
fuse
If there is no power supply to the stove, check the state of the fuse
located in the box between the stove switch and the power cable
connection.