Displays
Display
Reason
off
Generator off
sTaRT
The start-up phase is in progress
pelleT feeDinG
Continuous pellet feeding is in progress during the ignition phase
iGniTion
The ignition phase is in progress
pRepaRaTion
The
preparation
phase is in progress
WoRk
The normal work phase is in progress
MoDulaTion
The generator is working at minimum
BloW
The automatic blow is active
final cleaninG
The final cleaning is in progress
sTanD-By
Generator off waiting for re-ignition due to an external thermostat
coolinG WaiTinG
A new ignition is attempted when the generator has just been switched off. When the generator switches off, one must wait for
the complete shutdown of the fumes motor, then clean the burn pot. The generator can only be re-ignited when these operations
have been performed.
H-off
Generator off due to water temperature over set
T - off
Generator off waiting for re-ignition due to all requests met
Black ouT WaiTinG
The generator is cooling after a power cut.
Once cooling is completed, it will re-start automatically
anTi-fReeze
The anti-freeze function is in progress as the H2O temperature is below the factory set threshold
the pump is active until the water reaches the pre-set factory par2°C
anTi-Block
The pump anti-block function is in progress (only if the generator has been in an OFF state for at least 96 hours); the pump is
activated for the time pre-set by the manufacturer, in order to prevent it from blocking
seRvice
When this message appears, contact the technician authorised to perform routine maintenance on the device. If the cleaning is
not performed, the message will appear at every start-up but without interrupting the normal operation of the stove.
alaRMs
Display
eXplanaTion
soluTion
Indicates the presence of an alarm.
On: indicates the presence of an alarm.
Flashing: indicates the deactivation of the depression sensor
The alarm can only be reset if the fumes motor has stopped and 15 minutes have
passed since the alarm was displayed, by pressing key 1/
for 3 seconds.
fuMes MoToR
faulT
Fumes motor fault
Contact after-sales centre
fuMes pRoBe
Flue gas probe fault.
Contact after-sales centre
cHaMBeR pRoBe
Chamber probe fault.
Contact after-sales centre
HoT fuMes
High fumes temperature
Check pellet feed (see “EASY SETUP”), if the problem cannot be solved,
contact an authorised technician.