ENGLISH
easy setup
The volumetric weight of the pellet is the ratio between the weight and the volume of the pellet. This ratio may change while keeping the
quality of the pellet unchanged. By using the easY seTUP function, it is possible to change the calibration of the volumetric weight by
increasing or decreasing the pre-set values.
in the stove program, the available values go from “– 3” to “+ 3”; all stoves are calibrated during production with the optimal value which is 0
if you notice an excessive deposit on the burning pot, access the easY seTUP program and lower the value to “- 1”; then wait until the next
day and if there is no improvement, decrease again, to a maximum of “- 3”.
instead, if it is necessary to increase the calibration of the volumetric weight of the pellet, go from the factory value “0” to “+ 1, + 2, + 3” as
required.
EXCESSIVE PELLET dEPOSIT IN THE BURNING POT
NORmAL OPERATION
mINImUm PELLET dEPOSIT IN THE BURNING POT
-3
-2
-1
0
+1
+2
+3
THirD
DeCrease
raNge iF THe
FirsT TwO are
NOT eNOUgH
seCOND
DeCrease
raNge iF THe
FirsT is NOT
eNOUgH
FirsT DeCrease
raNge (TesT
FOr 1 DaY)
OPTimaL FaCTOrY
VaLUe
FirsT iNCrease
raNge
seCOND
iNCrease
raNge iF THe
FirsT is NOT
eNOUgH
THirD iNCrease
raNge iF THe
FirsT TwO are
NOT eNOUgH
CONTrOLs PrOCeDUre
Press key 6.
Press key 3 until
EASY SETUP
appears and confirm by pressing key 6.
Use keys 4 and 5 to set the range.
Press key 6 to confirm and key 1 to return to the previous menus to the initial state.
n.B.: if this CaliBration does not solve the pellet deposit in the Burn pot, please ContaCt your loCal
after-sales Centre.
Chrono
This function allows the stove's ignition and switch-off to be automatically programmed.
The factory setting for
CHRONO
is off.
The chrono allows the programming of 4 time slots within a day, which can be used every day of the week.
ignition and switch-off times can be set for each time slot, along with the specific days of application for the programmed time slot,
the desired temperature and power setting.
Current day and time settings are essential for the correct operation of the Chrono.
Recommendations
Before using the chrono function, you must set the current day and time, so check that you have followed the points listed in the
sub-chapter “dATE-TImE”. To use the chrono function correctly, you must activate it as well as program it. The four time slots can be
overlapped using the time switch on and off settings, This allows you to obtain a combination of times in which you can set different
temperatures and power without influencing the stove work status.
NB: if overlapping time slots are set, the stove will stay on until the latest switch-off time.