0
1
2
3
4
5
6
7
0
0,5
1
1,5
2
2,5
3
3,5
ENGLISH
cHecks and measures for commissioning
caution!
for correct generator operation, tHe Hydraulic system pressure must be between 0.6 and 2.5 bar.
Whenever the pressure detected by the digital pressure switch is lower than 0.6 or over 2.5 bar, the boiler goes into alarm mode.
By taking the pressure of the water within standard values, the alarm can be reset by pressing the
/1
key for 3 seconds
(The alarm can be reset only if the fumes motor has stopped and 15 minutes have passed since the alarm was displayed)
tHe pellet load motor does not function:
It is normal that there is air inside the circuit due to filling the system.
On the 1st ignition cycle, the movement of the water causes the air bubbles to move and be bled by the system automatic venting. This can
cause the pressure to drop and the minimum pressure switch to intervene, which interrupts operation of the pellet conveying motor and
therefore operation of the heat generator.
The system must be bled several times to eliminate the air and loaded when the pressure is too low.
It is not an anomaly, but normal phenomenon, due to filling. After filling, the system must always be bled using the relevant vents in the circuit
and having the machine perform the “OUTLET AIR” function. (After commissioning and with the machine cold, activate the “OUTLET AIR”
function again. - see "SETTINGS" chapter)
bulb tHermostats - rearm
Check by pressing rearm (95°C) , before contacting a technician (see REARM chapter).
The diagram at the side illustrates the behaviour of the
pump used on our thermo-products at the speeds that can
be set.
flow rate (m
3
/h)
Head (m)
features
Water content of the thermo-product heat exchanger (l)
19
volume of expansion vessel integrated into thermo-product (l)
*8
3 bar safety valve integrated into the thermo-product
YES
Minimum and maximum pressure switch integrated into the thermo-product
YES
Pump integrated into the thermo-product
YES
Pump max. head (m)
6
*
Envision any inTEgraTivE Expansion vEssEl on ThE Basis of ThE sysTEm WaTEr conTEnT.