background image

ENGLISH

AddITIONAL wARNINGs

 

Š

Only use the fuel recommended by the manufacturer. The product must not be used as an incinerator.

 

Š

Do not use the product as a ladder or supporting structure.

 

Š

Do not place laundry on the product to dry it. Any clothes-horse or similar objects must be kept at due distance from the product. 

Danger of fire or damage to the coating.

 

Š

The user is fully liable for any incorrect use of the product. The manufacturer bears no civil or criminal liability for incorrect use.

 

Š

Unauthorised tampering of any nature or replacement of spare parts of the product with non-original parts may endanger the operator 

and the manufacturer bears no civil or criminal liability for this.

 

Š

Large parts of the surface of the product can get very hot (door, handle, glass, smoke outlet pipes, etc.). Please therefore avoid coming 

into contact with these parts without wearing suitable protective clothing or using appropriate measures, such as heat protective gloves. 

 

Š

DO NOT use the product with the door open or if the glass is broken.

 

Š

The product must be electrically connected to a system equipped with an operational earthing system.

 

Š

Turn off the product in the event of a failure or malfunctioning.

 

Š

Unburned pellets that build up in the burner following each failed start-up must be removed before attempting to start up the product 

again. Make sure that the burner is clean and correctly positioned before starting it up again.

 

Š

Do not wash the product with water. Water may penetrate into the unit and cause faults in the electrical insulation. This can cause 

electric shocks.

 

Š

Installations not complying with the regulations in force, as well as incorrect use and failure to comply with the maintenance scheduled 

by the manufacturer, will invalidate the guarantee.

37

Содержание 001282600

Страница 1: ...MADE IN ITALY design production VIRNA IDRO 004276851 rev 002 UK THERMO PRODUCTS USER MANUAL...

Страница 2: ...ENGLISH 2...

Страница 3: ...hermostat 21 Additional thermostat functioning with STAND BY active 21 Additional thermostat operation with STAND BY deactivated 21 Additional thermostat installation 21 easy setup 22 CHRONO 22 Enabli...

Страница 4: ...IMP RATIF Avant de d placer le po le retirer le rev tement indiqu pour viter tout dommage ACHTUNG PFLICHT Bevor der Ofen bewegt wird muss die angezeigte Verkleidung entfernt werden um Sch den zu verme...

Страница 5: ...ITH REDUCED PHYSICAL SENSORY OR MENTAL CAPACITIES OR WITHOUT EXPERIENCE OR THE NECESSARY KNOWLEDGE PROVIDED THAT THEY ARE SUPERVISED OR HAVE RECEIVED INSTRUCTIONS ON SAFE USE OF THE APPLIANCE AND THAT...

Страница 6: ...r ignition During the filling phase do not put the bag of pellets to into contact with the product The majolicas aretop quality artisan products and as such can have micro dots crackles and chromatic...

Страница 7: ...at the documentation has been provided and must keep it with a copy of the technical documentation relating to the installation For installation in a condominium prior approval from the condominium s...

Страница 8: ...lection cap must be provided at the base of the vertical section If the exhaust is not inserted in an existing flue a vertical section with a windproof end piece is required UNI 10683 The vertical duc...

Страница 9: ...for passive houses because it does not take air in from within the house combustion air To ensure the stove remains hermetically sealed the connection pipe for the combustion air must be directly con...

Страница 10: ...and inspection of correct functioning must be carried out perfectly in full compliance with Standards in force national regional and municipal as well as these instructions For Italy installation mus...

Страница 11: ...harge into the flue This is to prevent unexpected power increases The flue fitting can be mounted between the boiler and the flue only after this inspection An inspection of the connections with pre e...

Страница 12: ...output T3 Boiler return input Virna IDRO details Combustive air rear inlet Lower fumes exhaust Upper fumes exhaust Combustive air side inlet Pellet hopper pressurised closure Heat exchanger scrapers E...

Страница 13: ...conveying motor and therefore operation of the heat generator The system must be bled several times to eliminate the air and loaded when the pressure is too low It is not an anomaly but normal phenome...

Страница 14: ...gnitionthestovewillgointo DEPRALARM mode while during normal operation the stove will go into COOLING WAITING TIME mode and then re start automatically when the correct conditions are present stove co...

Страница 15: ...be seasoned in order to obtain a sufficiently adequate heat yield THE USE OF POOR QUALITY PELLETS OR ANY OTHER MATERIAL DAMAGES THE FUNCTIONS OF THE GENERATOR AND CAN VOID THE WARRANTY AND THE ANNEXED...

Страница 16: ...external additional thermostat is closed and the STAND BY function is enabled Flashing with contact open the contact of the external additional thermostat is open and the STAND BY function is enabled...

Страница 17: ...must be followed the first times the stove is ignited It is possible that slight odours are produced due to the drying of the paints and silicone used Do not remain in the room for long periods Do not...

Страница 18: ...15 Decrease Decreases the value displayed 16 Stove status Displays the general status of the stove Battery type and replacement The battery is housed in the lower part of the remote control To replac...

Страница 19: ...d key 1 to return to the previous menus to the initial state Language This menu allows the preferred language to be selected The languages available are Italiano English German French Spanish Portugue...

Страница 20: ...d the stove will re start automatically and continue the working phase returning to the selected power level MODULATION and H OFF As the water temperature approaches the set point the boiler starts to...

Страница 21: ...inside the stove and relative factory setting restrictions If the stove is in H OFF water temperature reached any additional contact or thermostat request will be ignored Additional thermostat operati...

Страница 22: ...ENOUGH Controls procedure Press key 6 Press key 3 until easy setup appears and confirm by pressing key 6 Use keys 4 and 5 to set the range Press key 6 to confirm and key 1 to return to the previous m...

Страница 23: ...FF 00 00 PRG1 stop time Monday Sunday On off Enabling disabling days for PRG1 Set prg1 65 C 80 C 149 F 176 F Set thermostat PRG1 Power prg1 1 5 Set power PRG1 prg2 Start prg2 OFF 00 00 PRG2 start time...

Страница 24: ...02 00 23 00 08 00 16 30 t 02 00 23 00 08 00 16 30 t 3 1 02 00 23 00 08 00 16 30 t 72 68 2 1 Time slot 1 start 02 00 stop 23 00 power 3 set temp 72 C Time slot 2 start 08 00 stop 16 30 power 1 set tem...

Страница 25: ...via an additional thermostat Controls procedure Press key 6 Press key 3 until SETTINGS appears and confirm by pressing key 6 Continue by pressing key 3 until STAND BY appears and confirm by pressing k...

Страница 26: ...Press 3 until SETTINGS appears and confirm by pressing 6 Press key 3 until OUTLET AIR appears and confirm by pressing key 6 Use keys 4 and 5 for enabling ON or disabling OFF Press key one several time...

Страница 27: ...use abrasive or chemically aggressive detergents for cleaning The ceramic glass must be cleaned when the glass is completely cold To clean the ceramic glass simply use a dry brush and some damp newspa...

Страница 28: ...burn pot using the poker supplied Re position the burn pot in its seat and push it towards the fire wall Replace the pellet chute assembly on the burn pot Make sure that the burn pot and pellet chute...

Страница 29: ...ENGLISH EVERY 30 DAYS Cleaning the combustion chamber deflector Remove the deflector and eliminate the ash deposited in the upper part of the deflector 29...

Страница 30: ...physically and a pellet chute assembly B When cleaning and removing the burn pot remove the pellet chute assembly B by lifting it see figure Perform the same operation in reverse order to re assemble...

Страница 31: ...product warranty GASKETS pellet hopper lid DOOR ASH DRAWER AND BURN POT The gaskets guarantee the tightness of the stove and its consequent good functioning They must be controlled periodically They m...

Страница 32: ...let hopper ash drawer and door replace them and apply silicone where envisioned C Combustion chamber and heat exchanger full cleaning including ignition plug pipe D Hopper complete emptying and cleani...

Страница 33: ...llet hopper ash drawer and door replace them and apply silicone where envisioned C Combustion chamber and heat exchanger full cleaning including ignition plug pipe D Hopper complete emptying and clean...

Страница 34: ...it will re start automatically Anti freeze The anti freeze function is in progress as the H2O temperature is below the factory set threshold the pump is active until the water reaches the pre set fact...

Страница 35: ...tre MAX H20 PRESSURE ALARM Air in the system Inadequate circulation Possible air in the system bleed the system Lack of adequate circulation Lack of or inadequate safety zone The water in the stove ha...

Страница 36: ...ity to use the product and wrong maintenance by the consumer with respect to what is reported and recommended by the instructions manual of the product which is part of the sales contract this guarant...

Страница 37: ...t pipes etc Please therefore avoid coming into contact with these parts without wearing suitable protective clothing or using appropriate measures such as heat protective gloves DO NOT use the product...

Страница 38: ...ENGLISH 38...

Страница 39: ...ENGLISH 39...

Страница 40: ...lame it www lanordica extraflame com TO FIND THE SERVICE CENTRE NEAREST TO YOU CONTACT YOUR DEALER OR CONSULT THE SITE WWW LANORDICA EXTRAFLAME COM The manufacturer reserves the right to vary the char...

Отзывы: