18
GB
GB
GB
GB
GB
Timer mode 4 [P27 = 5]
Timer mode 4 [P27 = 5]
Timer mode 4 [P27 = 5]
Timer mode 4 [P27 = 5]
Timer mode 4 [P27 = 5]
The instrument operates using SP set point and
the timer is normally reset.
When the instrument detects the transfer from
contact open to close it selects SP2 as operative
set point and starts the time count down.
When the time count is equal to 0 the instrument
comes back to the SP set point.
0316 display management
0316 display management
0316 display management
0316 display management
0316 display management: when the
instrument starts the time count down, the upper
display shows the measured value while the
lower display shows time count down.
0216 display management
0216 display management
0216 display management
0216 display management
0216 display management: when the
instrument starts the time count down, the
display shows the time count down.
Pushing pushbutton it is possible to display
the measured value.
NOTE
NOTE
NOTE
NOTE
NOTE: for both instruments, when the time is
finished the instrument comes back to the normal
display mode.
Timer mode 5 [P27 = 6]
Timer mode 5 [P27 = 6]
Timer mode 5 [P27 = 6]
Timer mode 5 [P27 = 6]
Timer mode 5 [P27 = 6]
The instrument start in "Power OFF" mode and it
remains in "Power OFF" mode until the contact is
closed.
When the contact has been opened the
instrument starts the control using SP set point
and starts the time count down.
When the time count is equal to 0 the instrument
comes back to the "Power OFF" mode and the
output 2 will be energized.
The Out 2 reset will be made when the logic input
will be closed.
0316 display management
0316 display management
0316 display management
0316 display management
0316 display management: when the instrument
starts the time count down, the upper display
shows the measured value while the lower display
shows time count down.
0216 display management
0216 display management
0216 display management
0216 display management
0216 display management: when the instrument
starts the time count down, the display shows the
time count down.
Pushing pushbutton, it is possible to display
the measured value.
NOTE
NOTE
NOTE
NOTE
NOTE: for both instruments, when the time is
finished the instrument comes back to the usual
display of the Power OFF mode.
Closed
Open
SP2
SP
Open
Open
Time
Logic input
SP
Time
Output 2
OFF
OFF
ON
OFF
Contact
Closed
Open
Open
Closed
Stop
Run
Stop
Run
Stop
Run
Output
Power
OFF
Output
Power
OFF
02-0316-1-DER.pmd
22/04/2004, 16.19
18
Содержание 216
Страница 39: ...B 5 216 316 A 00NEW pmd 22 04 2004 15 18 5 ...