13
GB
GB
GB
GB
GB
Timer mode 4 [P27 = 5]
Timer mode 4 [P27 = 5]
Timer mode 4 [P27 = 5]
Timer mode 4 [P27 = 5]
Timer mode 4 [P27 = 5]
The instrument operates using SP set point and
the timer is normally reset.
When the instrument detects the transfer from
contact open to close it selects SP2 as operative
set point and starts the time count down.
NOTE:
NOTE:
NOTE:
NOTE:
NOTE: that the guarantee soak function can be
applied to this timer mode (see P28 parameter)
When the time count is equal to 0 the instrument
comes back to the SP set point.
For other details see paragraph "5.7 Timer
"5.7 Timer
"5.7 Timer
"5.7 Timer
"5.7 Timer
modes description".
modes description".
modes description".
modes description".
modes description".
Timer mode 5 [P27 = 6]
Timer mode 5 [P27 = 6]
Timer mode 5 [P27 = 6]
Timer mode 5 [P27 = 6]
Timer mode 5 [P27 = 6]
The instrument start in "Power OFF" mode and it
remains in "Power OFF" mode until the contact is
closed.
When the contact has been opened the instrument
starts the control using SP set point and starts the
time count down.
NOTES:
NOTES:
NOTES:
NOTES:
NOTES:
1) The guarantee soak function can be applied to
this timer mode (see P28 parameter)
2) The transfer from "Power OFF" mode to
AUTOMATIC mode starts the "Soft start" and
the "alarm masking" functions (if programmed).
When the time count is equal to 0 the instrument
comes back to the "Power OFF" mode and the
output 2 will be energized.
The Out 2 reset will be made when the logic input
will be closed.
For other details see paragraph "5.7 Timer
"5.7 Timer
"5.7 Timer
"5.7 Timer
"5.7 Timer
modes description".
modes description".
modes description".
modes description".
modes description".
Timer mode 6 [P27 = 7]
Timer mode 6 [P27 = 7]
Timer mode 6 [P27 = 7]
Timer mode 6 [P27 = 7]
Timer mode 6 [P27 = 7]
The instrument starts in "Power OFF" mode and
it remains in "Power OFF" mode until the contact
is closed.
When the contact has been opened the
instrument operate as follows:
- it starts the control using SP set point.
- it starts the time count down
- it energizes the Output 2
NOTES:
NOTES:
NOTES:
NOTES:
NOTES:
1) The guarantee soak function can be applied to
this timer mode (see P28 parameter)
2) The transfer from "Power OFF" mode to
AUTOMATIC mode starts the "Soft start" and
the "alarm masking" functions (if programmed).
When the time count is equal to 0 the instrument
comes back to the "Power OFF" mode and the
output 2 will be reset.
For other details see paragraph "5.7 Timer
"5.7 Timer
"5.7 Timer
"5.7 Timer
"5.7 Timer
modes description".
modes description".
modes description".
modes description".
modes description".
02-0316-1-DER.pmd
22/04/2004, 16.19
13
Содержание 216
Страница 39: ...B 5 216 316 A 00NEW pmd 22 04 2004 15 18 5 ...