Operation & Software Manual
96
Direct Drives & Systems
Chapter C: System functions
ETEL Doc. - Operation & Software Manual # DSC2P 903 / Ver. F / 3/6/05
12.4.5 Vpower DC bus voltage
Parameters
K146, K147, K148
and
K149
are used to give the errors and warnings limits values of the input
voltage.
Remark:
Each axis of the DSCDL has its own parameters K146, K147, K148 and K149 whose values is
used for +Vpower and -Vpower.
•
For the DSC2P / DSC2V
, monitoring
M91
is used to indicate the DC input voltage level (Vpower).
•
For the DSCDL
, monitorings
M91
and
M92
are used to indicate the positive and negative DC input voltage
level (respecVpower and -Vpower).
12.4.6 Fuse check
Parameter K140 allows the user to enable or disable the check of the fuse protecting the supply of the encoders
Remark:
On the DSC2P, this parameter can be used only from the DSC2Pxxx-xxxC version.
It is also possible to monitor the state of this fuse with monitoring M140.
Remark:
If the check of the fuse is enabled and if the fuse is broken, the
ENCODER FUSE KO
error
(M64=35) will appear.
Available on
DSC2P
DSC2V
DSCDP
DSCDL
DSCDM
K
Name
Value
Comment
Units
K146
Vpower
undervoltage
warning
0
> 0
Disables test on Vpower
Warning activated: Vpower level is tested.
If Vpower[V]*100<K146, the controller generates a
W UNDER VOLTAGE
warning M66=10)
[V]*100
K147
Vpower
undervoltage
error
0
> 0
Disables test on Vpower
Error activated: Vpower level is tested.
If Vpower[V]*100<K147 the controller generates an
UNDER VOLTAGE
error (M64=9)
[V]*100
K148
Vpower
overvoltage
warning
0
> 0
Disables test on Vpower
Warning activated: Vpower level is tested.
If Vpower[V]*100> K148, the controller generates a
W OVER VOLTAGE
warning (M66=4)
[V]*100
K149
Vpower
overvoltage
error
0
> 0
Disables test on Vpower
Error activated: Vpower level is tested.
If Vpower[V]*100 > K149, the controller generates an
OVER VOLTAGE
error (M64=6)
[V]*100
M
Name
Comment
Units
M91
Vpower measurement
Gives the DC input voltage level (Vpower): Vpower[V] = M91 / 100
[V]*100
M
Name
Comment
Units
M91
+Vpower measurement Gives the positive DC input voltage level (+Vpower): +Vpower[V] = M91 / 100
[V]*100
M92
-Vpower measurement Gives the negative DC input voltage level (-Vpower): -Vpower[V] = M92 / 100
[V]*100
Available on
DSC2P
DSC2V
DSCDP
DSCDL
DSCDM
K
Name
Value
Comment
K140
Mask for fuse control
0
1
Enables the test of the fuse
Disables the test of the fuse
M
Name
Value
Comment
M140
Fuse status
0
1
Fuse is not broken
Fuse is broken
Содержание DSC Series