ETEL Doc. - Operation & Software Manual # DSC2P 903 / Ver. F / 3/6/05
Chapter E: Appendixes
Operation & Software Manual
Direct Drives & Systems
305
D
S
CDM p
arameters
10
Homing on a single index with detection of limit switch
12
Homing on a multi-index
14
Homing on a multi-index with detection of limit switch
16
Homing on a single index with choosen DIN (K58
bit3:DIN1, bit4:DIN9) at 1
18
Homing on a single index with choosen DIN (K58
bit3:DIN1, bit4:DIN9) at 1 with detection of limit switch
20
Homing on multi-index with a defined stroke (K46). If no
index has been met, the controller generates an error
(M64=62)
22
Immediate homing at the current position (It is used to
take K53 at a known position into account)
24
Single index homing with defined stroke (K46). If no
index has been met, the controller generates an error
(M64=62)
26
Homing on single index. If the motor reaches a
mechanical end stop before an index, it changes its
movement direction. If after the mechanical end stop it
does not meet an index before a stroke defined by K46,
the controller generates an error (M64=62)
34
Homing on a single index with detection of limit switch
coming from the encoder
36
Homing on home switch. If the motor reaches a
mechanical end stop before home switch, it changes its
movement direction. If after the mechanical end stop it
does not meet home switch before stroke defined by
K46, the controller generates an error (M64=62)
38
Homing on single index after having found mechanical
end stop with defined stroke (K46). If no index has been
met, the controller generates an error (M64=62)
K41
Homing speed
2000000
1
2147483647
K42
Homing acceleration
1000000
256
2147483647
K43
Homing tracking limit for mechanical end stop detection
10000000
0
2147483647
K44
Homing force limit for mechanical end stop detection
4096
0
32767
K45
Offset on absolute position
0
-2147483648 2147483647
K46
Stroke for K40 = 20, 21, 24, 25 homing mode
0
0
2147483647
K47
Movement to go out of a limit switch or mechanical end
stop at the end of the homing
0
0
2147483647
K48
Movement to go out of an index or home switch if the
motor is on the top of it when starting the homing
0
0
2147483647
K50
Set point calculator shift value: 1dpi = 2^K50 * 1upi
0
0
8
K52
Enables fine phase adjustment (takes K53 into account)
after homing
0
0
1
K53
Motor commutation phase adjustment after homing (is
taken into account only if K52=1)
0
0
2048
K54
Pairs of pole of the motor (=1 for linear motor)
1
1
2147483647
K55
Motor commutation encoder: number of dpi per
revolution for rotary motor or number of dpi per magnetic
period for linear motor
0
0
2147483647
K56
Motor commutation phase inversion enabled
0
0
1
K58
Limit switch mode
0
0
10
0
Limit switch mode DIN9 and DIN10
1
Limit switch mode L1/L2
K
Alias
Val
<P1>
Bit #
<P1>
Comment for parameters K
and <P1> of the DSCDM
Def. Val
<P1>
Min. Val
<P1>
Max. Val
<P1>