ETEL Doc. - Operation & Software Manual # DSC2P 903 / Ver. F / 3/6/05
Chapter E: Appendixes
Operation & Software Manual
Direct Drives & Systems
259
15.28 WPG, WPL, WSG, WSL example
:10.2
;Label 10
MMD.2=17
;Sets the rotary S-curve movement
PWR.2=1
;Power on
WTM.2
;Waits until the movement is finished
IND.2
;Starts the homing
WTM.2
;Waits until the movement is finished
POS.2=0.00000
;Goes to the position 0 (ISO unit)
WTM.2
;Waits until the movement is finished
X10.2=100
;Sets user’s variable X10 of axis 2 to 100
:30.2
;Label 30
WPG.2=M50.2,2
;Waits for the value of monitoring M50 of axis 2 to be greater than the value 2
POS.2=20.0000
;Goes to the position 20 (ISO unit)
WTM.2
;Waits until the movement is finished
WTT.2=1.00000
;Waits for 1 (ISO unit)
POS.2=0.00000
;Goes to the position 0 (ISO unit)
WTM.2
;Waits until the movement is finished
WTT.2=1.00000
;Waits for 1 (ISO unit)
:40.2
;Label 40
WPL.2=M50.2,2
;Waits for the value of monitoring M50 of axis 2 to be lower than the value 2
POS.2=10.0000
;Goes to the position 10 (ISO unit)
WTM.2
;Waits until the movement is finished
WTT.2=2.00000
;Waits for 2 (ISO unit)
POS.2=0.00000
;Goes to the position 0 (ISO unit)
WTM.2
;Waits until the movement is finished
WTT.2=2.00000
;Waits for 2 (ISO unit)
JMP.2=30
;Jumps to label 30
Remark:
WSL and WSG commands work respectively like WPL and WPG commands but in this case the
parameters <P1> and <P2> can be signed.