K40 = 37:
Same as K40 = 36 but with a negative movement.
K40 = 38:
Homing on a mono-reference mark but only after having found the mechanical end stop. Once found, the motor
moves back the distance given by parameter K47 and finds the reference mark with the distance given by
parameter K46. If the index is not found within the distance given by parameter K46, the
SING IDX SEARCH
error (M64=62) appears (the distance given by parameter K46 must be smaller than the one between both
mechanical end stop).
K40 = 39:
Same as K40 = 38 but with a negative movement.
MOTOR
K46
K47
0
Motor braking distance (variable)
The '0 machine' is found