Operation & Software Manual
192
Direct Drives & Systems
Chapter C: System functions
ETEL Doc. - Operation & Software Manual # DSC2P 903 / Ver. F / 3/6/05
13.8.6 RTI programming examples
13.8.6.1 Example 1: ’Window test’ type
Tests if the X1 variable is inside the limit defined by X2 and X3.
Set the DOUT1, if it is the case.
Sequence:
:5.1
;Start of the sequence.
X1.1=0
;Sets the X1 variable
X2.1=20
;Sets the X2 variable
X3.1=40
;Sets the X3 variable
R0:8.1=22
;Type of RTI.
R0:9.1=255
;Does not jump to a label.
R0:10.1=1
;Does not wait on the 'wait' command
R0:1.1=0x00010001
;Variable to test X1
R0:2.1=0x00010002
;Inferior limit, X2 variable
R0:3.1=0x00010003
;Superior limit, X3 variable
R0:4.1=0x000200ab
;Bit to modify, DOUT1 (parameter K171)
K191.1=1
;Valid RTI line
K192.1=1
;Enables the RTI line
RIE.1
;Sets the controller RTI enable mode
13.8.6.2 Example 2: ’Bit test' type
Test if the din1 comes to 1 and jump to label 200.
P3 is not included, because P4 = 0 in this case.
Sequence:
:5.1
;Start of the sequence.
R0:8.1=3
;Type of RTI.
R0:9.1=200
;Jumps to label 200.
R0:10.1=1
;Does not wait on the 'w..' command
R0:1.1=0x00030032
;Bit 0 of DIN1 (M50).
R0:2.1=8
;State 1
R0:4.1=0
;No modification of P3
K191.1=1
;Valid RTI line
K192.1=1
;Enables RTI line
RIE.1
;Sets the controller RTI enable mode
:200.1
;Label 200.
…..
;Commands
K193.1=0
;Resets the flag
REI.1
;Back to the sequence and RTI activation