DSCDL
mo
nit
o
ring
s
35
The fuse of the encoder supply is broken
36
Error when the label of a jump or a call is greater than
511
37
Error when the controller executes a command at a
sequence line number greater than 8190
38
This error occurs when the register number is greater
than its maximum value
39
This error occurs when the stack is overflowed (256
times)
40
This error occurs when K79 as a wrong value
41
This error occurs when K89 as a wrong value
56
Time-out error in TEB communication. This error is
checked only if bit#1 of K141 is set
59
There are several nodes that have the same number on
the TEB
60
Error in homing process when leaving home switch or
limit switch. Checks K48 parameter or DIN 2, 9 or 10.
This error occurs when after the trip from K48 the home
switch or limit switch is present
61
Error in multi-index homing process. Checks K43, K44
and K75 parameters. This error occurs when the motor
has reached the two mechanical end stops (detections
are done by K43 and K44) without having finished the
homing process (for linear motors)
62
Error in single index homing process. Checks K43 and
K44 parameters. This error occurs when the motor has
reached the two mechanical end stops (detections are
done by K43 and K44) without having finished the
homing process (for linear motors)
63
Error in start synchro on input (STI command)
65
Error when the real position (M7) is out of the limits
defined by K34 and K35 when bit#1 of K36 is set
66
Error when the reference position is out of the limits
defined by K34 and K35 when bit#2 of K36 is set
67
Movement not possible because the controller is not in
power on mode
68
PWR ON not possible because the controller is in
interpolation mode (by ITP=1)
69
Homing is not possible due to the configuration of the
controller and the setting
80
Framing error on EBL2
81
Overrun error on EBL2
82
Checksum error on EBL2 message
84
Input buffer full on EBL2
85
Bad CRC on EBL2 in received message in CRC Mode
88
Other axis error on EBL2
100
Optional board error 100. See optional board manual
101
Optional board error 101. See optional board manual
102
Optional board error 102. See optional board manual
103
Optional board error 103. See optional board manual
104
Optional board error 104. See optional board manual
105
Optional board error 105. See optional board manual
M
Alias
Values
Bit #
<P1>
Comment for monitorings M
and <P1> of the DSCDL
Def. Val
<P1>
Min. Val
<P1>
Max. Val
<P1>