15.10 JBS, JBC example
:10.0
;Label 10
PWR.0=1
;Power on
WTM.0
;Waits until the movement is finished
IND.0
;Starts the homing
WTM.0
;Waits until the movement is finished
SPD.0=360.000
;Sets the maximum speed to 360 (ISO unit)
ACC.0=300.000
;Sets the maximum acceleration to 300 (ISO unit)
X10.0=0
;Sets user’s variable X10 of axis 0 to 0
:20.0
;Label 20
XAC.0=X10.0
;Puts the value of the user’s variable X10 of axis 0 in the accumulator (XAC)
JBS.0=0,30
;If the bit# 0 of the accumulator is equal to 1, the execution goes on from label 30
JBC.0=0,40
;If the bit# 0 of the accumulator is equal to 0, the execution goes on from label 40
JMP.0=20
;Goes to label 20
:30.0
;Label 30
POS.0=100.0
;Goes to the position 100 (ISO unit)
WTT.0=1.00000
;Waits for 1 (ISO unit)
POS.0=0.00000
;Goes to the position 0 (ISO unit)
WTT.0=1.00000
;Waits for 1 (ISO unit)
JMP.0=20
;Goes to label 20
:40.0
;Label 40
POS.0=10.0
;Goes to the position 10 (ISO unit)
WTT.0=2.00000
;Waits for 2 (ISO unit)
POS.0=0.00000
;Goes to the position 0 (ISO unit)
WTT.0=2.00000
;Waits for 2 (ISO unit)
JMP.0=20
;Goes to label 20