![Essen BioScience IncuCyte ZOOM Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/essen-bioscience/incucyte-zoom/incucyte-zoom_user-manual_2428338020.webp)
Page 20
NOTE:
This version of the IncuCyte™ Control Software is not backwards compatible with IncuCyte™
microscopes that are running earlier versions of the software. Contact Essen BioScience technical
support for instructions for updating controller software.
7.
Click on the “Go” button to the right of the address bar. If the controller is found
on the network, you will be prompted for a User name and password. Press the
“Cancel” button to exit. If the controller is not found, then a “Cannot Find”
message will be displayed after a brief search period.
4.2 Static IP Based Networks
In order to reconfigure the IncuCyte™ ZOOM controller for a static IP address, a direct connection
must first be made to the controller. In order to accomplish this you will need to connect a
monitor, keyboard and mouse to the controller. To gain access to the monitor, keyboard and
mouse ports you need to unscrew the two screws on the back of the controller and remove the
back cover (See Figure 8).
With the controller powered down, connect the monitor, keyboard and mouse to the controller.
After connecting, power up the controller. Once Windows has booted up you can log in with a
User name "ZoomAdmin" and the Essen-provided password.
Recall that the ultimate goal is to configure the controller’s primary Ethernet port with a static IP
address selected for your corporate network. Once on the desktop, the controller’s primary
Ethernet port can be configured with a static IP address in the same way that the PC’s primary
port was configured. Use the Windows 7 instructions for the controller configuration. After
configuring the primary Ethernet port, log off of the controller’s desktop. Unplug the monitor,
keyboard and mouse from the back of the controller and reinstall the cover on the back of the
controller.
Chapter 5: Installation of the IncuCyte™ Control Software
The IncuCyte™ ZOOM control software is used to both configure the instrument to collect data and for
post-collection viewing and analysis of these data. This software is designed to run on PC’s running
Windows XP, Windows Vista or Windows 7 and requires an Administrator account to install.
Contact Essen BioScience Support (refer to section 2.3 for support contact information) to get the most
recent version of the software. Once downloaded, run the installer by double clicking on the installer
file.
5.1 IncuCyte™ Control Software Installation using Windows XP
1.
Review the license agreement. To continue installation you must agree.
2.
Select components you want to install.
3.
Choose a destination folder and Install.
4.
Install the Windows Media Player Codecs. (Required to save movies).