Product Specification for RBS 2302
Power Consumption
Normal operation, both TRXs transmitting on full
output power (at 230 V nominal mains supply):
<140 VA
Maximum power consumption:
<500 VA (only with
activated heater).
The optional fan-unit (at 230 V nominal mains
supply):
<15 VA
Battery Backup
The RBS will survive interruptions on mains supply for at least 3
minutes. The RBS will maintain full performance during the backup
time if the battery is fully charged. The battery will be recharged to at
least 80% of its capacity within 15 hours.
For longer backup time an external UPS or PBC may be used.
Battery Backup (PBC)
The Battery Backup Time is further specified in chapter Site
Configuration, RBS 2000 Micro.
5.8.8
Type Approval
Type Approval Standard
The RBS 2302 fulfils the required type approvals from: GSM 11.20 or
GSM 11.21 standard JTC standard FCC rules and regulations.
According to requirements in Section Product Safety Requirements RBS
2000.
Product Safety
The RBS 2302, 1900 MHz is listed by the National Recognized Testing
Laboratory (NRTL).
EMC
The RBS complies with the European Community market requirements
regarding EMC for Base station equipment. The product has the CE
sign to show this compliance.
The RBS complies with the US market requirement regarding EMC for
Base station equipment. The product has the FCC sign to show this
compliance.
The RBS fulfils the electromagnetic requirements for Base station Radio
meeting Phase 2 GSM requirements according to ETS 300 342–3.
EN/LZT 123 2697
R5A
1998-08-13
69 (306)
© Ericsson Radio Systems AB
— All Rights Reserved —