![Ericsson CME 20 R6.0 Скачать руководство пользователя страница 262](http://html1.mh-extra.com/html/ericsson/cme-20-r6-0/cme-20-r6-0_reference-manual_2422935262.webp)
EMC Capabilities for RBS 2301
Table 41
Surge test 10/700 pulses
Limit standard
IEC 1000-4-5
Test level
1 kV common mode between line and cabinet ground reference
1 kV differential mode between line and line
Performance
Criteria B for a complete system
Criteria TT for transmitter units
Criteria TR for receiver units
Table 42
Power induction test
Basic standard
ITU-T K.20
Test level
600 V(rms) common mode
Performance
Criteria A(K.20)
Table 43
RF common mode test
Limit standard
ETS 300 342-2
Test level
10 V(rms)
Performance
Criteria A for a complete system
Criteria CT for transmitter units
Criteria CR for receiver units
39.3.6
Radiated Immunity of Enclosure Port
Table 44
Immunity of continuous electric fields
Basic standard
IEC 801-3
Test level
10 V/m
Performance
Criteria A
Limit standard
ETS 300 342-2
Test level
10 V/m, 80 MHz - 1 GHz
Frequency range
30 V/m, 1 GHz-20 GHz
Performance
Criteria A for a complete system
Criteria CT for transmitter units
Criteria CR for receiver units
Table 45
Immunity of 50/60 Hz magnetic fields
Basic standard
IEC 1000-4-8
Test level
10 A/m, 50/60 Hz
Performance
Criteria A
EN/LZT 123 2697
R5A
1998-08-13
261 (306)
© Ericsson Radio Systems AB
— All Rights Reserved —