EMC Capabilities for RBS 2302
RF Common Mode: PBC
No requirements are applicable for the PBC.
40.4.3
Conducted Immunity on intra-connecting signal ports
Fast Transient Test: RBS
Table 64
Fulfills the EEC type approval certification requirements according to:
Product standard
prETS 300 342-3, October 1997
Basic standard
EN 61 000-4-4, 1995
Test level
0.5 kV common mode between all lines and cabinet ground
reference.
Performance
Criteria TT
Criteria TR
Note:
see note 40.4
Fast Transient Test: PBC
Table 65
Fulfills the EEC self certification requirements according to:
Generic standard
EN 50 082-1, 1992
Basic standard
IEC 801-4, 1988
Test level
0.5 kV common mode between all lines and cabinet ground
reference.
Performance
Criteria B
Note:
see note 40.4
RF Common Mode: RBS
Table 66
Fulfills the EEC type approval certification requirements according to:
Product standard
prETS 300 342-3, October 1997
Basic standard
EN 61 000-4-6, 1996
Frequency range
150 kHz - 80 MHz
Test level
3 V(rms)
Performance
Criteria CT
Criteria CR
Note:
see note 40.4
RF Common Mode: PBC
Note:
see note 40.4
EN/LZT 123 2697