![Ericsson CME 20 R6.0 Скачать руководство пользователя страница 276](http://html1.mh-extra.com/html/ericsson/cme-20-r6-0/cme-20-r6-0_reference-manual_2422935276.webp)
EMC Capabilities for RBS 2302
40.4.5
Conducted Immunity For Direct Lightning Strike
RBS, PBC:
Note:
see note 40.4
40.4.6
Radiated Immunity of enclosure port, electric fields
RBS
Table 70
Fulfills the EEC type approval certification requirements according to:
Product standard
prETS 300 342-3, October 1997
Basic standard
EN 61 000-4-3, 1995
Test level
3 V/m
Frequency range
80 MHz - 1 GHz
Performance
Criteria CT
Criteria CR
Note:
see note 40.4
PBC
Table 71
Fulfills the EEC self certification requirements according to:
Basic standard
IEC 801-3, 1984
Test level
3 V/m unmodulated signal
Frequency range
27 MHz - 500 MHz
Performance
Criteria A
Note:
see note 40.4
40.4.7
Radiated Immunity of enclosure port, magnetic fields 50/60 Hz
RBS, PBC:
Note:
see note 40.4
40.4.8
Electro-static Discharges, Immunity of enclosure port
RBS
Table 72
Fulfills the EEC type approval certification requirements according to:
Product standard
prETS 300 342-3, October 1997
Basic standard
EN 61 000-4-2, 1995
Test level
Contact discharge 4 kV
Air discharge 8 kV
EN/LZT 123 2697
R5A
1998-08-13
275 (306)
© Ericsson Radio Systems AB
— All Rights Reserved —