SC-F9200 Series
Revision B
DISASSEMBLY & ASSEMBLY
Disassembly and Assembly Procedure
162
SE Group Confidential (Related Staff Only)
10. Move the CR Unit until to a position over the platen.
11. Remove the CR Timing Belt from the pinion gear of the CR Motor.
12. Release the CR Motor Cable from the clamp.
13. Disconnect the cable from the relay connector.
14. Remove the two screws and the plate, and remove the CR Motor.
C) Silver M4x10 screw: 2 pcs
Figure 3-101. Removing the CR Motor
When installing the CR Motor, make sure to install it in the correct
orientation as shown in
.
C
C
- Right side -
CR Timing Belt
CR Motor Cable
Clamp
Relay
connector
CR Motor
Plate
Pinion gear