SC-F9200 Series
Revision C
TROUBLE SHOOTING
Remedies for Print Quality Troubles
63
SE Group Confidential (Related Staff Only)
Bandings in the paper feeding direction.
The Print Head has not been adjusted
properly.
---
Carry out the following adjustments.
CR Direction Head Slant Adjustment
PF Direction Head Slant Adjustment
The paper was not fed properly.
---
Carry out the following adjustment.
Feed amount adjustment
Check the following settings.
Feed Adjustment
Media Tension
PF Scale or PF Encoder failure
1. Is the PF Scale damaged or contaminated?
2. Is the PF Scale attached properly?
3. Is the PF Encoder installed correctly?
1. Clean the PF Scale.
2. Reinstall the PF Scale and PF Encoder.
3. Replace the PF Scale
and PF
Encoder
.
The tension of the PF Timing Belt is not
proper.
---
Correct the tension of the PF Timing Belt.
PF Motor failure
---
Replace the PF Motor.
Table 2-5. Print Quality Troubles
Symptom
Cause
Check Item
Remedy