SC-F9200 Series
Revision B
DISASSEMBLY & ASSEMBLY
Disassembly and Assembly Procedure
157
SE Group Confidential (Related Staff Only)
3.4.5.7 CR Scale
1.
2.
Open the Right Maintenance Cover.
3.
Open the Left Maintenance Cover.
4.
Open the Front Cover.
5.
On the left side of the printer, remove the tension spring.
6.
Move the CR Unit to the left end.
7.
On the right side of the printer, disengage the CR Scale from the hook on the
frame.
Figure 3-96. Removing the CR Scale
8.
Release the CR Scale from each hook of the four CR Scale Holders.
Figure 3-97. Removing the CR Scale
9.
Pull out the CR Scale from the CR Scale.
A D J U S T M E N T
R E Q U I R E D
When replacing/removing this part, refer to
Items and the Order by Repaired Part” (p260)
and make sure to
perform the specified operations including required adjustment.
C A U T I O N
Do not contaminate the surface of the CR Scale with ink,
fingerprints, skin oil, or any other dirt. And be extremely careful
not to scratch or damage the surface by letting it come in contact
with the main unit frames or any other things. Doing so may result
in malfunction of the CR Unit.
When installing the CR Scale, confirm the following.
Attach one side with “L” print to the left side of the printer.
Attach one side with “R” print to the right side of the printer.
Left Side
CR Scale
Tension spring
Groove
Hook
- Left side -
- Right side -
Hook
CR Scale
CR Scale Holder
Hook
Front Cover
CR Scale Holders
Содержание SC-F9200 series
Страница 11: ...SE Group Confidential Related Staff Only C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 37: ...SE Group Confidential Related Staff Only C H A P T E R 2 TROUBLESHOOTING ...
Страница 76: ...SE Group Confidential Related Staff Only C H A P T E R 3 DISASSEMBLY ASSEMBLY ...
Страница 258: ...SE Group Confidential Related Staff Only C H A P T E R 4 ADJUSTMENT ...
Страница 365: ...SE Group Confidential Related Staff Only C H A P T E R 5 MAINTENANCE ...
Страница 389: ...SE Group Confidential Related Staff Only C H A P T E R 6 APPENDIX ...