SC-F9200 Series
Revision C
ADJUSTMENT
Overview
262
SE Group Confidential (Related Staff Only)
CR related
parts/units
IM Sensor
Replacement
1
Replacement
---
√
√
After
replacement
2
Turn the power on in Serviceman mode.
---
√
√
3
Ink Mark Sensor Check & Auto Adjustment
√
√
---
CR Encoder
Replacement
1
Replacement
---
√
√
After
replacement
2
Turn the power on in normal mode.
---
√
√
3
CR Belt Tension Check
√
Tensimeter U-507
√
√
4
APG function check
√
√
√
5
CR Scale Check
√
√
√
6
CR Active Damper Adjustment (Automatic)
√
√
√
7
CR Motor Measurement & Automatic Adjustment
√
√
√
8
Head inclination manual adjustment (CR direction)
√
PGPP
√
√
9
Head slant manual adjustment (PF direction)
√
PGPP
√
√
10
Manual Uni-d adjustment
√
PGPP
11
Manual Bi-d adjustment
√
PGPP
12
Reset the encoder counter.
√
√
---
Head related
parts/units
Print Head
Before
replacement
1
Turn the power on in normal mode.
---
√
---
2
Dispose of waste ink.
---
√
---
3
Reset the waste ink counter
---
√
---
4
Activate the ink cartridges for service.
√
√
---
5
Turn the power off.
---
√
---
6
Remove the ink tanks.
---
√
---
7
Install the ink cartridges for service.
---
√
---
8
Turn the power on in Serviceman mode.
---
√
√
Replacement
9
Auto CR unlock & move CR to full column side
√
√
√
10
Replacement
---
√
√
Table 4-1. Adjustment items and the order by repaired part
Class
Replaced or Repaired
(Reattached) Part/Unit
Required Operations
Service
Program
Jig
Media
Replaced
Reattached
Page
Содержание SC-F9200 series
Страница 11: ...SE Group Confidential Related Staff Only C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 37: ...SE Group Confidential Related Staff Only C H A P T E R 2 TROUBLESHOOTING ...
Страница 76: ...SE Group Confidential Related Staff Only C H A P T E R 3 DISASSEMBLY ASSEMBLY ...
Страница 258: ...SE Group Confidential Related Staff Only C H A P T E R 4 ADJUSTMENT ...
Страница 365: ...SE Group Confidential Related Staff Only C H A P T E R 5 MAINTENANCE ...
Страница 389: ...SE Group Confidential Related Staff Only C H A P T E R 6 APPENDIX ...