SC-F9200 Series
Revision C
ADJUSTMENT
CR Related Adjustments
301
SE Group Confidential (Related Staff Only)
4.10.2 APG Function Check
EXECUTION MODE
Normal Mode
PROCEDURE
1.
Remove the following parts in advance.
Right Cover
2.
Turn the printer ON.
3.
Start the Service Program and select
APG function check
.
4.
Click
[Run]
.
The APG mechanism moves.
Figure 4-19. [APG function check] Screen
5.
Check that the mark on the top of the APG cam is “++”.
Run the check two times and check the mark.
“Typ” is on the top: Go to
“Typ” is not on the top: Go to
Figure 4-20. Checking the APG cam
++
Mark on the top
APG cam