SC-F9200 Series
Revision C
ADJUSTMENT
CR Related Adjustments
299
SE Group Confidential (Related Staff Only)
9.
<Belt tension measurement>
Input the following values to the tensimeter.
MASS: 1.0
g/m
WIDTH: 10.0
mm/R
SPAN: 1170
mm
10. Bring the microphone of the tensimeter closer to the position shown in
11. Press
[MEASURE]
on the tensimeter and flip the belt with tweezers or a similar
tool.
12. Measure the belt tension for three times, and check if the average is within the
standards.
Within the standards: Go to
Out of the standards: Go to
13. Click
[Finish]
.
14. Turn the printer OFF to finish the adjustment.
C H E C K
P O I N T
Bring the microphone within 5 mm from the belt but do not let it
touch the belt.
C A U T I O N
Be sure to measure the tension of the belt on the upper side. If
you measure the tension of the belt on the lower side, the
measuring value may be inaccurate.
Flip the belt as weak as the tensimeter can measure it.
Be careful not to let the microphone touch the belt when
flipping the belt.