ADJUSTMENT
CR Related Adjustments
300
SE Group Confidential (Related Staff Only)
Figure 4-17. Measuring the belt tension
15. Loosen the two screws that secure the driven pulley holder.
16. Turn the adjustment screw to adjust the belt tension.
If larger than standard value: Turn the screw counterclockwise.
If smaller than standard value: Turn the screw clockwise.
After adjusting the tension, tighten the screws loosened in
, and then back
to
.
Figure 4-18. Tension adjustment screw
Upper timing belt
Measuring microphone
Center
(Measurement point)
CR Unit
Driven Pulley
C H E C K
P O I N T
The tension is changed about 1.58N by turning the adjusting screw
for a quarter turn.
Tension adjustment
screw (black)
Screws