background image

The 

Full Screen

 allows displaying the image in the full S/VGA screen, with little or no window ''frame'' around the image. A mouse

click, anywhere on the S/VGA, restores the previous mode. The XCAP-Lite version does not provide the 

Full Screen

 feature.

The 

Always-On-Top

 allows forcing the image viewer window, and its subwindows, to always be ''above'' other windows; subject to

the other windows' also requesting 

Always-On-Top

, and the whims of the host operating system. This option is typically useful only

when XCAP is being used in combination with other applications, such as in conjunction with the PIXCI® TWAIN Sourcery or
PIXCI® Image-Pro Sourcery feature.

The 

Refresh

 forces the displayed image to be redrawn once; normally manual refresh is not needed, but occasionally, when the

image was (partly) covered and uncovered by other window(s), the displayed image might ''forget'' to be updated.

For images composed of index pixels and palette, the 

Image's Palette

 allows manipulating the image's attached palette; for images

of other types, the 

Image's Palette

 is not selectable. For all images, the 

Viewer's Palette

 allows manipulating a palette which is not

attached to the image. Either can be used for contrast enhancement, adjustment of black level and gain, or, for monochrome
images, false coloring. Either, or neither, of the palettes can be selected for use under 

Misc Options

.

For image sequences, the 

Sequence Play

 allows ''playing'' the sequence, image by image, at a selected rate. The 

Sequence

Thumbnails

 shows a window in which each image of the sequence is a small ''snapshot''; clicking a snapshot selects that image for

display by the image viewer window. The XCAP-Lite version does not provide the 

Sequence Thumbnails

.

The 

Cursor

 allows activating a cursor over the image, which may be positioned via coordinates, or by clicking the mouse on an

image feature.

The 

Display

 allows selecting how the image is displayed: (a) No resizing so that there is a one to one relationship between an

image pixel and a displayed S/VGA pixel and is quickest, although the entire image may not fit within the window and must
therefore be panned and scrolled, (b) Resize by nearest neighbor which is relatively quick, or (c) Resize by bilinear interpolation
which may produce better results for continuous tone images, but is slower. For the resize modes, the aspect ratio can also be
modified. For the image viewer window associated with the PIXCI imaging board's frame buffer(s), the 

Display

 provides

additional features, identical to the 

Live Options

 described below.

The 

Zoom, Pan, Scroll

 allows magnifying the displayed image, and panning and scrolling to view different portions of the image

under magnification. For image sequences, a specific image of the sequence can be selected for display. In addition to panning
and scrolling via explicit coordinates and via scrollbars, holding the right mouse button and moving the mouse over the image also
implements panning and scrolling.

The 

Misc Options

 allows selecting which palette, if any, is to be used during display and during file loads and saves. An option to

display only even lines, or only odd image lines, allows avoiding interlace artifacts during display.

Each image buffer (sequence) may have several simultaneously active viewers, allowing, for example, viewing the same image
buffer both magnified and unmagnified. The 

Launch 2nd Viewer

 creates a second image viewer window into the same image buffer

(sequence), with the same features as the original image viewer window. The XCAP-Lite version does not provide the 

Launch 2nd

Viewer

 feature.

5.2.3. Image Viewer - Examine

The image viewer window's 

Examine

 provides options to examine the image.

The 

Pixel Peek

 allows numeric display of the pixel values in the vicinity of the image cursor.

The 

Pixel Peek & Poke

 allows numeric display and modification of the pixel value at the image cursor.

The 

Pixel Plot

 displays a two dimensional graph of pixels values along a selected image line or column, all image lines, or for

image sequences, a vector. Features attached to the graph show specific pixel values and descriptive statistics such as lowest
value, highest value, mean value, and standard deviation. The XCAP-Lite version does not provide a graph of all image lines, and
does not provide descriptive statistics.

The 

Pixel Plot 3D

 displays a three dimensional graph projection of the image.

The 

SMPTE VITC

 allows searching the image for valid SMPTE Vertical Interval Time Codes and displaying the decoded codes.

The XCAP-Lite version does not provide the 

SMPTE VITC

 features.

5.2.4. Image Viewer - Modify

The image viewer window's 

Modify

 provides image processing operations which modify the image, modify each image

(independently) in a sequence (typically named ''Sequence ...'') or modify one or more images in a sequence by combining data
from across multiple images (typically named ''... Sequence ).''

PIXCI® SV4 User's Manual

http://www.epixinc.com/manuals/pixci_sv4/index.htm

28 of 50

1/29/2016 11:23 AM

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание PIXCI SV4

Страница 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Страница 2: ...I are registered trademarks of EPIX Inc Other brand product and company names are trademarks or registered trademarks of their respective owners Printing 3 Dec 2001 Table of Contents 1 Installation 1...

Страница 3: ...5 2 4 Image Viewer Modify 5 2 5 Image Viewer Measure 5 2 6 Image Viewer Draw 5 2 7 Image Viewer AOI 5 2 8 Image Viewer View Shortcuts 5 2 9 Image Viewer View Status Bar 5 2 10 PIXCI Image Viewer Captu...

Страница 4: ...Remove the PIXCI SV4 imaging board from the antistatic bag and push it into the PCI bus connector This can require up to 15 pounds of force Do not use too much force as the board may not be inserted i...

Страница 5: ...rs The PIXCI SV4 imaging board has four connectors which are accessible thru the bracket that mounts the board to the computer chassis From the top of the bracket to the bottom the connectors are Y C...

Страница 6: ...d XCAP Imaging Application Click OK ii Follow the installation program s directions such as to select an installation directory iii b If XCAP is provided via the internet Download ftp epixinc com soft...

Страница 7: ...ization key utility program c For USB port authorization keys in some versions of Windows 95 and 98 it is also necessary to Start Settings Control Panel Add New Hardware d Note that support for the US...

Страница 8: ...eo Capture Board which appears if a PIXCI imaging board driver was previously installed Select Specify the location of the driver Advanced Click Next Select Search for the best driver for your device...

Страница 9: ...rocedures The EPIXXCW5 VXD EPIXXC32 VXD for version 2 0 and earlier must be copied to the Windows SYSTEM directory typically C WINDOWS SYSTEM 1 Using the Registry Editor REGEDIT provided with Windows...

Страница 10: ...EY_LOCAL_MACHINE Enum PCI VEN_165A DEV_D201 BUS_ DEV_ FUNC_ Win 98 HKEY_LOCAL_MACHINE Enum PCI VEN_165A DEV_D201 SUBSYS_00000000 REV_ BUS_ DEV_ FUNC_ or the existing entry for PIXCI CL3SD Win 95 HKEY_...

Страница 11: ...e obtained by limiting the amount of memory recognized by Windows ME and then instructing EPIXXCW5 VXD to explicitly use a section of memory without allocating it from Windows Restrict Windows to use...

Страница 12: ...eractive index program will be executed automatically Otherwise execute the index program from a command prompt or via the Windows Start Run Z SETUP replace Z with drive letter for your CD i Select Se...

Страница 13: ...loaded when the PC was powered up as described under Hardware Installation instruct Windows to load the appropriate driver Click Start Programs and Windows NT Explorer Within the chosen installation...

Страница 14: ...I Video Setup Resolution As the frame buffer memory is allocated once during Windows initialization the contents of frame buffers are retained as XCAP is closed and restarted but lost if Windows is re...

Страница 15: ...wed by off line analysis or saving of the sequence 3 4 4 Windows NT Authorization Key Manual Installation Use of HLDINST EXE above provides automatic installation of the printer port authorization key...

Страница 16: ...several TXT files The TXT files contain these installation instructions a list of distributed files corrections or additions to this manual or other up to date information One file PCITIPS TXT contai...

Страница 17: ...roller then instruct Windows to load the appropriate driver Click Start Settings Control Panel System if System is not listed click on view all Control Panel options Device Manager and Other Devices o...

Страница 18: ...ed during Windows initialization The requested frame buffer memory size must be specified in the Registry entry described above using an entry named PIXCI such as PIXCI IM memorysize replacing the mem...

Страница 19: ...he amount of memory available 2 Reboot using the newly added boot selection 3 For example for a PC with 1 gigabyte of memory allocating 256 Mbyte for Windows and the remainder for frame buffer memory...

Страница 20: ...The camera has been connected to the PIXCI imaging board b The XCAP software has been installed c For XCAP Plus or XCAP Std but not XCAP Lite the authorization key has been installed on the printer po...

Страница 21: ...windows c Select whether the Shortcuts and or Adjust features appear automatically or only when Capture Adjustments or Capture Shortcuts are clicked or d Remove the status bar increasing the screen a...

Страница 22: ...o Setup to start anew with the default video format resolution and video input 4 4 Capturing Images Once the PIXCI imaging board is opened for use images may be captured from the PIXCI Image Viewer cl...

Страница 23: ...lution and window size the entire image may not fit If the image doesn t fit then a Scroll bars appear allowing the viewed portion of the image to be panned and scrolled throughout the entire image an...

Страница 24: ...ustry standard and the most commonly used image file format TIFF is suggested for saving and reloading an image into XCAP and suggested for exporting images to other programs which support TIFF The JP...

Страница 25: ...ures this manual typically refers to all versions as XCAP except where explicitly differentiated The XCAP programs are organized into two major types of windows the Image Viewer Window and the Main Wi...

Страница 26: ...her means which are recorded A recorded script is in a human readable form and can be altered with any common editor capable of handling ASCII text allowing scripts to be modified or combined A select...

Страница 27: ...5 1 5 Main Window PIXCI The main window s PIXCI allows initiating access to the PIXCI imaging board and provides configuration options Actual operation of the PIXCI imaging board is performed through...

Страница 28: ...as a single TIFF or AVI format image file with multiple images The XCAP Lite version does not support loading or saving of image buffer sequences in a single operation however multiple uses of Load Im...

Страница 29: ...ard s frame buffer s the Display provides additional features identical to the Live Options described below The Zoom Pan Scroll allows magnifying the displayed image and panning and scrolling to view...

Страница 30: ...other distributions to an image The Sequence Noise Generator does the same on each image of a sequence The Src Dst Noise Generator does the same with distinct source and destination images The Normal...

Страница 31: ...gles While these capabilities are also available elsewhere in Image Viewer Measure and Image Viewer Draw the Distance Angle Crosshairs collects chosen features to provide a single window with the equi...

Страница 32: ...sing printing load and save features will operate The Set ROI defines the default region of interest and color space upon which future image measurement analysis and other selected features which acce...

Страница 33: ...tradeoffs between capture rate vs convenience vs total number of images captured The Video to Frame Buffers captures sequences directly into pre configured frame buffer memory and can support any vide...

Страница 34: ...rollPad a miniature scroll bar which overlays the displayed number allowing adjustment of the numeric value with mouse clicks and drags iii Selecting units and range for display of angles such as 0 to...

Страница 35: ...ogram Setup Windows Info Window Style Java Info Devices Volpi intralux dc 1100 Illumination Technologies 3900 PIXCI PIXCI Open Close Board Info Driver Assistant PIXCI Video Setup Format dependent on i...

Страница 36: ...ndows Print PXIPL Duplicate Image Copy to Black Board Attributes Close Viewer View Shortcuts Adjustments Status Bar Full Screen Always On Top Refresh Image s Palette Viewer s Palette Black Gain Numeri...

Страница 37: ...agnitude Kirsch Edge Magnitude Roberts Edge Gradient Log Sobel Edge Gradient Log Sobel Absolute Edge Gradient Log Kirsch Edge Gradient Log Roberts Edge Gradient Thin Minimal Effect Edge Gradient Thin...

Страница 38: ...Dst Src Bit Wise XOR Dst Src Bit Wise OR Dst Src Average Src Dst 2 Product c0 Src c1 c2 Dst c3 c4 Product c0 Dst c1 c2 Src c3 Ratio c0 Dst c1 c2 Src c3 User Defined f PixA PixB Pair Normalization Src...

Страница 39: ...Disk File Single Sequence Video to Disk File Single Sequence w Event Start Video to Disk File Single Sequence w Event per Image Video to Disk File Continuous Sequence Video to Disk File Continuous Se...

Страница 40: ...e Comparison Feature XCAP Plus XCAP Std XCAP Lite XCAP Demo File Load New Image Yes Yes Yes u No Load New Image Sequence Yes Yes No No Image File Info Yes Yes Yes Yes TWAIN Select Source Yes Yes No No...

Страница 41: ...age Sequence Yes Yes No No E Mail Image Yes Yes No No Print Windows Yes Yes Yes No Print PXIPL Yes Yes No No Duplicate Image Yes Yes No No Copy to Black Board Yes Yes No No View Full Screen Yes Yes No...

Страница 42: ...ithmetic Yes Yes No No Pair Normalization Yes Yes No No Sequence Average Yes Yes No No Difference Sequence Yes Yes No No Tile Sequence Yes Yes No No Measure Intensity Calibration Yes Yes No No Spatial...

Страница 43: ...No No Elliptical Annulus Arc Yes Yes No No Path Enclosed Yes Yes No No Polygon Yes Yes No No Rectangular Frame Yes Yes No No Graphic Manager Yes Yes Yes Yes Image Overlay Yes Yes No No Paint Brush Yes...

Страница 44: ...ration e The Capture Adjustments do not include save load or export For color cameras with Bayer output the white balance software feature allows creating a single set of customized settings f The Lin...

Страница 45: ...the color C component of S Video A chroma comb filter may be enabled or disabled by software The chrominance U component gain can be selected from values of 0 to 201 18 The chrominance V component gai...

Страница 46: ...host computer s memory or can be passed to other devices on the PCI bus such as disk controllers or S VGA adapters 6 1 11 Display Image display is not a function of the PIXCI SV4 imaging board however...

Страница 47: ...PAL Resolution Depth 8 bit RS 170 CCIR YUV 4 2 2 NTSC PAL YCrCb S Video Capture Display Rate 30 fps S Video NTSC RS 170 25 fps S Video PAL CCIR 7 0 2 Bus Requirements 32 bit 33 MHz PCI slot 0 55 Amps...

Страница 48: ...ually all applications board level programming can be ignored XCOBJ automatically recognizes different versions and options of the PIXCI imaging cards providing consistent access to features and hidin...

Страница 49: ...shorted the input or output will not be connected properly Try another cable Test the video or DB15 cable for shorts or opens with an ohmmeter Test the video cable by connecting the video source direc...

Страница 50: ...gulator and crystal oscillators 2 Changes from PIXCI SV2 Added second BNC connector Video encoder now handles 3 video inputs 1 Added video input low pass filters for each of the BNC inputs These filte...

Страница 51: ...ion of implied warranties so the above limitations may not apply to you If this product is not in good working order as warranted above your sole remedy shall be repair or replacement as provided abov...

Страница 52: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...