8
EN
Technical data
Voltage (power supply):
400 V 3 N AC 50 Hz
Switching capacity:
max. 9 kW resistive load, may be extended with a power
extension unit (LSG)
Fuse
3 x 16 A
Heating time limit:
6 h / 12 h / unlimited
Housing:
plastic, shatter-resistant
Display:
TTFT colour display 55 x 74 mm (3,5“ size)
Operation:
5 capacitive buttons on the control panel
Protection type:
IPx4 in accordance with EN 60529, splashproof
Temperature control range:
30° - 115°C (dry sauna mode)
30° - 70°C (humid sauna mode - only H series models)
Humidity control:
proportional to time or optionally as per rel. air humidity
(%) with
an optional humidity sensor.
Sensor system:
Digital sensor with oveheating protection fuse (STB) 139°C
Control characteristic:
Digital two-point control
Connection for fan:
min. 5 W, max.150 W (only fans without starting capacitor)
Only use fans suitable for phase control!
Connection for light:
• min. 5 W (20 mA)
• resistive loads - max. 100 W,
• dimmable energy saving lamps - max. 35 W
• Lamps at conventional transformers - max. 60 VA.
Attention: only dimmable lamps may be used!
!
Fan and light output share a common 2AF fuse.
Volt-free output:
contact’s resistive load carrying capacity:
maximum current: 16 A
maximum voltage: 30 V DC / 250VAC
Start time pre-selection:
up to 24 h in advance
Switching automation:
Week timer with 4 switching programs per day
Error display:
Clear text error indication on the display
Outputs:
3 x RJ10 jacks for sensor connections
2 x RJ14 jacks for control panel and extension modules
1 x potential free contact (2 terminals)
Output S1:
maximal load 50 W / 50 VA, no capacitive loads allowed.
Terminal block area for power
supply and heater connection:
0.5 – 2.5 mm² rigid or flexible crimped wire, two cores with
the same cross section per terminal may be connected
Terminal block area WM, 3, 4,
light, fan:
0.34 – 2.5 mm² rigid or flexible crimped wire. Please observe
the minimal cross section as per fuse protection of the line!