24
EN
1. The humidity sensor shall be mounted in the
middle of the wall opposite to the heater at
approx.
150 cm
height.
2. Connect the sensor using the included cable
(5 m standard, longer line optionally availal-
be). Draw the cable with the RJ10 plug to-
wards the control unit.
3. Connect the sensor cable to the sensor
board, as shown in the diagram:
4. Make sure to connect the cable pins to the
sensor correctly. Incorrect connection may
damage the sensor!
5. Then connect the sensor cable via RJ10 plug
to the free sensor bus jack in the relay box.
6. The successful connection of the humidity
sensor the humidity symbol will change from
to
(humid operation mode) to
indicate humidity control as per relative air
humidity. The humidity sensor will be nor-
mally detected within 2-3 sec. These symbols
will appear on active humidity mode either
directly on the start screen (Emotec, Emo-
Style models) or in a submenu for settings
(EmoTouch series).
Notice: During installation of the cable DO
NOT pull it by the plug - this may damage
the plug connection!
Sensorbus
RJ 10
reserviert
reserved
Bankfühler
2nd sensor
Feuchtefühler
Humidity sensor
Ofenfühler
Main sensor
STB
B
}
Saunabus
RJ 14
}
RJ
10
RJ
14
RJ
10
RJ
10
RJ
14
Humidity
sensor installation
10
100
90
80
70
60
50
40
30
20
0
100
90
80
70
60
50
40
30
20
10
T
[°C]
rH
[%]
Temperature/humidity curve as per norm
EN 60335-2-53:2003
1. The humidity control with connected humi-
dity sensor effects basing on the tempera-
ture-humidity curve which serves as a limit
to possible values. You may set any value to
the left and below the curve as shown below.
2. Values above the curve may not be set for
safety reasons. If you change one parameter,
the other will be automatically adjusted to
keep the climate within safe limits.
3. Without humidity sensor, the humidity con-
trol is time-proportional. The humidity set-
ting e. g. “40“ means that the vaporizer will
be on for 40 % of the total operating time.
This method does not consider the real hu-
midity in the sauna, but allows to produce
contstant amount of steam per given time.
4. With the connected humidity sensor, the
humidity will be controlled as per relative air
humidity in %. The control unit will try to re-
ach and keep the pre-set humidity value.
white
green
brown
Humidity control with connected
humidity sensor
Connection over-
view of tempera-
ture sensor, bench
sensor and humidi-
ty sensor.