Two Plane Balancing with a Strobe Light
dataPAC User’s Guide
183
The dataPAC also calculates split vectors if weight needs to be divided between two
contiguous blades, rather than attached to a single blade. Press <F1> (VSplit On/Off) to
turn Vector Splitting off and on.
Always view the direction of rotation from the same point.
With machines having multiple positions, the reference blade is 1. For 8 positions,
correction weight call-outs may be at positions 1, 2, 3,... 8. The dataPAC automatically
splits the required correction weights between two adjacent blades if Vector Splitting is
turned on.
2.
With the correction weight attached securely, restart the machine and allow it to reach
normal operating speed.
3.
Press <STORE> to begin taking a residual measurement. You will take measurements
in both the first and second plane to see the affect of the correction weights in both
planes.
4.
Press the trigger on the strobe light and adjust the machine speed as before.
0
45
90
135
180
225
270
315
0
45
90
135
180
225
270
315
direction of
rotation
direction of
rotation
weight
weight
WITH rotation
AGAINST rotation
reference
mark
direction
of rotation
position 1
position 2
position 3
position 4
CLOCKWISE Rotation, MULTIPLE Positions
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com