background image

Please Read First

TR-701NW / 701AW

TR-702NW / 702AW

TR-702NW-H / 702AW-H

Part Names and Functions

[RIGHT SIDE]

TR-701NW / 702NW

TR-701AW / 702AW

[FRONT]

[BOTTOM]

[LEFT SIDE]

Sensor Jack
Channel 1

For connecting a sensor

REC/STOP Button*

Press to start or stop recording.

External Output 
Terminal

For connecting a siren, buzzer, or 
other warning device.

USB Port

For connecting to PC with USB cable

Sensor Jack
Channel 2

For connecting a sensor
(TR-701NW / 701AW only)

100/10 Indicator LED The orange LED will be on or off to indicate 

the communication speed.
ON: 100Mbps, OFF: 10 Mbps

Battery Case

Insert backup battery here.

LAN Port

For connecting LAN cable

POWER Button*

Press to turn ON or OFF the device.

LINK Display LED

If properly connected to a network device 
such as a hub, the LED will be on (green).

DISPLAY Button*

Press to change LCD display mode.

Power Monitor LED

While power is ON, the LED will be on (green).

INTERVAL 
Button*

Press to make or change recording 
interval settings or view currently 
set recording interval.

AC Adaptor Jack

For connecting the supplied AC adaptor

*  When [Button Lock] has been set to "ON" in the Settings Utility, the operation buttons will not be active.

Safety Precautions and Instructions

The following items should be strictly obeyed for the safe usage of this product, and for 

protecting yourself and other people from bodily harm and/or damage to property.

Explanation of Symbols

<Warning Symbols>

 DANGER

These entries are actions that, if taken, may cause serious personal 
physical damage or death.

 CAUTION

These entries are actions that if taken may lead to physical injury or 
damage to persons or things.

Explanation of Picture Symbols

Denotes an important 
warning or caution.

Denotes a forbidden 
action.

Denotes an action that 
should be carried out.

 DANGER

To Prevent Serious Accidents

Do not disassemble, repair or modify the unit and accessories.

Do not use the unit in any environment that is exposed to chemicals and harmful gases. 
Doing so may cause corrosion and/or other danger to the unit. Also, coming in contact 
with hazardous substances may cause bodily harm to the user or people nearby.
This unit is not water resistant. If water or a foreign object enters the case, immediately 
unplug the AC adaptor and stop using it.
Do not handle the unit, remove the battery or unplug the AC adaptor with wet hands.

This product has been designed for private and/or industrial use only. It should not be 
used in situations where strict safety precautions are necessary such as with medical 
equipment, or in systems directly or indirectly connected with human life or well-being.
Do not drop or expose the unit to a strong impact.

Do not connect any communication cables connected to the unit to telephone line outlets. 
Continued use may cause fire or electrocution.
Do not cut or process the cords for the AC adaptor or the communication cables. Also, do 
not twist, pull on or swing any of the cords.
To prevent damage to the unit from static electricity, remove static electricity from your 
body by touching metal around you (such as a door knob and window frame) before 
touching the unit.
Place and store the unit and accessories out of the reach of children.

We are not responsible for any damage, malfunction or trouble, whether direct or indirect, 
caused by the use of our product.
Do not use any power, battery, sensor, or cable other than those specified by T&D 
Corporation.
Do not put anything on top of the cable and/or AC adaptor. This may cause overheating.

Do not disconnect the communication cable during USB, LAN, or wireless communication. 
Doing so may cause adverse effects to the unit and/or PC.
Make sure that AC adaptor, sensor, and cable plugs are all inserted fully, so as not to 
cause an improper connection. Also, when unplugging the cable from the unit, do not pull 
the cord, but hold the connector to disconnect.
If the unit produces heat, emits smoke or a strange smell, or makes unusual noises, 
immediately unplug the AC adaptor, remove the batteries, and stop using it. Also, unplug 
the unit from the PC.
If the unit is not to be used for a long period of time, remove batteries. If left in the unit, the 
batteries may leak and lead to malfunctioning. Install new batteries when starting or 
re-starting to use a unit.

 CAUTION

Do not place or store in the following areas:

• Areas exposed to direct sunlight
• Areas exposed to excessive heat or high 

temperatures such as near fire or heating 
equipment

• Areas exposed to static electricity
• Areas exposed to strong magnetic fields

• Areas exposed to dampness
• Areas subject to condensation or wet areas
• Areas exposed to excessive vibration
• Areas exposed to excessive smoke, dust or 

dirt.

 CAUTION

Other Precautions

• Use the unit in the specified operating environment. Do not use it for any purpose other than for 

which it was designed.

• Condensation may occur inside the case when a unit is moved from one environment to another 

where there is a great difference in temperature.

• Do not use the unit in wet areas or places exposed to water such as bathroom.
• When connecting the unit to your PC, make sure to follow all warnings and directions from your 

computer manufacturer.

• We shall not guarantee the unit's operation if it has been connected to a PC using a USB hub or 

a USB extension cable.

• Do not insert any foreign objects into any of the units' jacks.
• If the unit gets dirty, wipe it with a clean cloth.
• Make sure to remove dust and dirt from plugs of the AC adaptor and/or any cables.
• Battery terminals may provide insufficient contact due to age or vibration. This may lead to data 

loss.

• If the unit is not to be used for a long period of time, for safety reasons please remove the 

battery. If left in the unit, the battery may leak and lead to malfunctioning.

• Please note that this Introductory Manual has been written based on the presupposition that 

details about contracts with an Internet provider, specific network environments and the set-up 
of any other necessary equipment to enable network connection has already been taken care 
of by the User and that connection has been confirmed as workable. T&D Corporation shall not 
be responsible for any damages which a contractor, a user or a third party may suffer, whether 
direct or indirect, due to the inability to communicate or use communication devices.

 CAUTION

Notices about Sensors

• Do not connect any sensor to the unit other than those specified by T&D Corporation.
• Make sure to use sensors within the measurement range indicated in the specifications for that 

sensor.

• If extremely severe temperature changes occur, it may result in large errors in humidity 

measurement. Once the sensor's temperature becomes stable, the measurements will return to 
normal.

• Do not connect the sensor to any data logger other than those specified by T&D Corporation.
• Do not expose the sensor to a strong impact. This may adversely affect measurement accuracy 

and cause damage or malfunction.

• When the sensor is not to be used for a long period of time, please store it at normal 

temperature and humidity.

• Do not use the sensor on the human body.
• Continued use may cause a decrease in the sensor’s accuracy and sensitivity even under 

normal operational conditions. If the sensor is being used in a smoky or dusty environment, 
the surface of the sensor will accumulate impurities causing a further decrease in the sensor's 
performance.

• The included sensor is not water resistant. Do not allow the sensor to become wet. If the sensor 

gets wet, immediately remove the sensor from the unit and wipe it with a clean cloth as soon as 
possible. Then allow the sensor to dry in normal room temperature before using it again.

• When using the THA-3151 in an environment where the humidity is under 30 %RH, the 

measurements may sometimes fluctuate. This is not abnormal.

• Do not expose to condensation, dampness, corrosive gases, or organic solvents (or insecticides 

for High Precision Temperature/Humidity Sensors).

Package Contents

TR-701NW / 701AW

TR-701NW / 701AW

Temperature 

Sensor

TR-0106 x 2

Common Accessories:

LAN Cable LN-20W x 1

(For TR-701NW / 702NW only)

USB Communication Cable 

US-15C x 1

AC Adaptor

AD-0638 or AD-06C1 x 1

Software CD-ROM x 1

Coin Type Lithium Battery

CR-2032 x 1

Manual Set (Warranty Included) x 1

- Getting Started Guide

- Please Read First

TR-702NW / 702AW

TR-702NW / 702AW

Temperature / 

Humidity Sensor

THA-3151 x 1

TR-702NW-H / 702AW-H

TR-702NW / 702AW

Temperature / 

Humidity Sensor

HHA-3151 x 1

Отзывы: