Please Read First
TR-701NW / 701AW
TR-702NW / 702AW
TR-702NW-H / 702AW-H
Part Names and Functions
[RIGHT SIDE]
TR-701NW / 702NW
TR-701AW / 702AW
[FRONT]
[BOTTOM]
[LEFT SIDE]
Sensor Jack
Channel 1
For connecting a sensor
REC/STOP Button*
Press to start or stop recording.
External Output
Terminal
For connecting a siren, buzzer, or
other warning device.
USB Port
For connecting to PC with USB cable
Sensor Jack
Channel 2
For connecting a sensor
(TR-701NW / 701AW only)
100/10 Indicator LED The orange LED will be on or off to indicate
the communication speed.
ON: 100Mbps, OFF: 10 Mbps
Battery Case
Insert backup battery here.
LAN Port
For connecting LAN cable
POWER Button*
Press to turn ON or OFF the device.
LINK Display LED
If properly connected to a network device
such as a hub, the LED will be on (green).
DISPLAY Button*
Press to change LCD display mode.
Power Monitor LED
While power is ON, the LED will be on (green).
INTERVAL
Button*
Press to make or change recording
interval settings or view currently
set recording interval.
AC Adaptor Jack
For connecting the supplied AC adaptor
* When [Button Lock] has been set to "ON" in the Settings Utility, the operation buttons will not be active.
Safety Precautions and Instructions
The following items should be strictly obeyed for the safe usage of this product, and for
protecting yourself and other people from bodily harm and/or damage to property.
Explanation of Symbols
<Warning Symbols>
DANGER
These entries are actions that, if taken, may cause serious personal
physical damage or death.
CAUTION
These entries are actions that if taken may lead to physical injury or
damage to persons or things.
Explanation of Picture Symbols
Denotes an important
warning or caution.
Denotes a forbidden
action.
Denotes an action that
should be carried out.
DANGER
To Prevent Serious Accidents
Do not disassemble, repair or modify the unit and accessories.
Do not use the unit in any environment that is exposed to chemicals and harmful gases.
Doing so may cause corrosion and/or other danger to the unit. Also, coming in contact
with hazardous substances may cause bodily harm to the user or people nearby.
This unit is not water resistant. If water or a foreign object enters the case, immediately
unplug the AC adaptor and stop using it.
Do not handle the unit, remove the battery or unplug the AC adaptor with wet hands.
This product has been designed for private and/or industrial use only. It should not be
used in situations where strict safety precautions are necessary such as with medical
equipment, or in systems directly or indirectly connected with human life or well-being.
Do not drop or expose the unit to a strong impact.
Do not connect any communication cables connected to the unit to telephone line outlets.
Continued use may cause fire or electrocution.
Do not cut or process the cords for the AC adaptor or the communication cables. Also, do
not twist, pull on or swing any of the cords.
To prevent damage to the unit from static electricity, remove static electricity from your
body by touching metal around you (such as a door knob and window frame) before
touching the unit.
Place and store the unit and accessories out of the reach of children.
We are not responsible for any damage, malfunction or trouble, whether direct or indirect,
caused by the use of our product.
Do not use any power, battery, sensor, or cable other than those specified by T&D
Corporation.
Do not put anything on top of the cable and/or AC adaptor. This may cause overheating.
Do not disconnect the communication cable during USB, LAN, or wireless communication.
Doing so may cause adverse effects to the unit and/or PC.
Make sure that AC adaptor, sensor, and cable plugs are all inserted fully, so as not to
cause an improper connection. Also, when unplugging the cable from the unit, do not pull
the cord, but hold the connector to disconnect.
If the unit produces heat, emits smoke or a strange smell, or makes unusual noises,
immediately unplug the AC adaptor, remove the batteries, and stop using it. Also, unplug
the unit from the PC.
If the unit is not to be used for a long period of time, remove batteries. If left in the unit, the
batteries may leak and lead to malfunctioning. Install new batteries when starting or
re-starting to use a unit.
CAUTION
Do not place or store in the following areas:
• Areas exposed to direct sunlight
• Areas exposed to excessive heat or high
temperatures such as near fire or heating
equipment
• Areas exposed to static electricity
• Areas exposed to strong magnetic fields
• Areas exposed to dampness
• Areas subject to condensation or wet areas
• Areas exposed to excessive vibration
• Areas exposed to excessive smoke, dust or
dirt.
CAUTION
Other Precautions
• Use the unit in the specified operating environment. Do not use it for any purpose other than for
which it was designed.
• Condensation may occur inside the case when a unit is moved from one environment to another
where there is a great difference in temperature.
• Do not use the unit in wet areas or places exposed to water such as bathroom.
• When connecting the unit to your PC, make sure to follow all warnings and directions from your
computer manufacturer.
• We shall not guarantee the unit's operation if it has been connected to a PC using a USB hub or
a USB extension cable.
• Do not insert any foreign objects into any of the units' jacks.
• If the unit gets dirty, wipe it with a clean cloth.
• Make sure to remove dust and dirt from plugs of the AC adaptor and/or any cables.
• Battery terminals may provide insufficient contact due to age or vibration. This may lead to data
loss.
• If the unit is not to be used for a long period of time, for safety reasons please remove the
battery. If left in the unit, the battery may leak and lead to malfunctioning.
• Please note that this Introductory Manual has been written based on the presupposition that
details about contracts with an Internet provider, specific network environments and the set-up
of any other necessary equipment to enable network connection has already been taken care
of by the User and that connection has been confirmed as workable. T&D Corporation shall not
be responsible for any damages which a contractor, a user or a third party may suffer, whether
direct or indirect, due to the inability to communicate or use communication devices.
CAUTION
Notices about Sensors
• Do not connect any sensor to the unit other than those specified by T&D Corporation.
• Make sure to use sensors within the measurement range indicated in the specifications for that
sensor.
• If extremely severe temperature changes occur, it may result in large errors in humidity
measurement. Once the sensor's temperature becomes stable, the measurements will return to
normal.
• Do not connect the sensor to any data logger other than those specified by T&D Corporation.
• Do not expose the sensor to a strong impact. This may adversely affect measurement accuracy
and cause damage or malfunction.
• When the sensor is not to be used for a long period of time, please store it at normal
temperature and humidity.
• Do not use the sensor on the human body.
• Continued use may cause a decrease in the sensor’s accuracy and sensitivity even under
normal operational conditions. If the sensor is being used in a smoky or dusty environment,
the surface of the sensor will accumulate impurities causing a further decrease in the sensor's
performance.
• The included sensor is not water resistant. Do not allow the sensor to become wet. If the sensor
gets wet, immediately remove the sensor from the unit and wipe it with a clean cloth as soon as
possible. Then allow the sensor to dry in normal room temperature before using it again.
• When using the THA-3151 in an environment where the humidity is under 30 %RH, the
measurements may sometimes fluctuate. This is not abnormal.
• Do not expose to condensation, dampness, corrosive gases, or organic solvents (or insecticides
for High Precision Temperature/Humidity Sensors).
Package Contents
TR-701NW / 701AW
TR-701NW / 701AW
Temperature
Sensor
TR-0106 x 2
Common Accessories:
LAN Cable LN-20W x 1
(For TR-701NW / 702NW only)
USB Communication Cable
US-15C x 1
AC Adaptor
AD-0638 or AD-06C1 x 1
Software CD-ROM x 1
Coin Type Lithium Battery
CR-2032 x 1
Manual Set (Warranty Included) x 1
- Getting Started Guide
- Please Read First
TR-702NW / 702AW
TR-702NW / 702AW
Temperature /
Humidity Sensor
THA-3151 x 1
TR-702NW-H / 702AW-H
TR-702NW / 702AW
Temperature /
Humidity Sensor
HHA-3151 x 1