96
CTC EcoLogic Pro/Family
For the installer
9.3
CTC EcoLogic systems 4 and 5*
The coniguration of EcoLogic systems 4 and 5 differ in terms of the location of
the additional heat source.
EcoLogic s
ystem 4
System 4 includes pool heating.
All heating from the heat pumps and additional heat goes to the heating circuit
through the buffer tank, which maintains a constant temperature to the heating
circuit.
In system 4, the additional heat is located
before
the hot water system, while in
EcoLogic system 5 it is located
after
the hot water system.
Heat pumps A1 and A2 can be connected using diverting valves that direct the
heat low either to the hot water system or to the heating circuit. The other heat
pumps are connected to the heating circuit.
Solar energy can be connected either to the hot water tank or to a buffer
tank using diverting valves, or to a ground heating loop. Cooling can easily be
connected to the bedrock/ground source heating system.
+
Heating circuit 4
Heating circuit 3
Heating circuit 2
Heating circuit 1
Fan convector
Solar panels
Additional heat
Cooling
Pool
Buffer tank
HP A1
HP A2
HP A3
HP A4 to A10
DHW
Alt. A
DHW tank
DHW OPT B
Brine circuit
*
The CTC EcoLogic Family,
systems 4 and 5, do not
include the following sub-
systems and their associ-
ated pumps, valves and
sensors:
-Heat pumps 3 to 10
-Heating circuits 3 and 4
-Cooling
-Recharging bedrock
-Solar energy
-Hot water circ. (DHW
CIRC.)
-External hot water tank
-Pool
Содержание CTC EcoLogic Family series
Страница 2: ......
Страница 3: ...162 105 48 3 2016 04 08 Installation and Maintenance Manual CTC EcoLogic Pro Family...
Страница 67: ...67 CTC EcoLogic Pro Family For the property owner...
Страница 120: ...120 CTC EcoLogic Pro Family For the installer 11 Wiring diagram...
Страница 121: ...121 CTC EcoLogic Pro Family For the installer...
Страница 127: ......
Страница 128: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 105 48 3 2016 04 08...