24
CTC EcoLogic Pro/Family
For the property owner
4.2.3
Night reduction temperature
This menu is used to activate and set a night reduction
temperature for each dei ned heating circuit. Night
reduction means that you reduce the temperature
indoors during scheduled periods, for example at night
or when you are at work.
The value by which the temperature is reduced –
Room
temp. reduced/ Primary l ow reduced – can be set in the
Installer/Settings/Heating circuit menu. The factory set
value is -2°C.
The options in the night reduction menu are
Off, Day by
day or Block. If you select Off, no reduction is made at
all.
Day by day menu
You use this menu to schedule a reduction on the days
of the week. This schedule is repeated every week.
Example 1:
Monday 06-09 18-21
On Monday the timer comes on from 06–09 and 18–21;
normal operation applies apart from these times.
Example 2:
Thursday
06 - --
-- - 21
The timer comes on from 06–21 on Thursdays.
Block
This menu allows you to set a reduction for a few
days during the week, for example, if you are working
elsewhere on weekdays and at home at weekends.
!
When both the Night reduction and Holiday settings are used, the Holiday function
overrides the Night reduction setting.
!
Reducing a heat pump’s tempera-
ture at night is a comfort setting
which generally does not reduce
energy consumption.
4.2.4
Holiday
The time on the left must be lower than the time on the right for
the interval to be valid.
On Sunday at 10 pm, the temperature is lowered by the set
value in the
Room temp. reduced menu (in the Installer/Settings
menu). On Friday at 2 pm the temperature is increased to the
set value again.
You use this option to set the number of days that you
want the set temperature to be constantly reduced. For
example, if you want to go on holiday.
The value by which the temperature is reduced –
Room
temp. reduced/ Primary l ow reduced – can be set in the
Installer/Settings/Heating circuit menu.
You can apply this setting for up to 300 days.
The period starts from the time for which the setting has
been made.
06 - 09
18 - 21
07 - 09
20 - 23
06 - 09 08 - 21
06 - --
-- - 21
06 - --
-- - 21
10 - 12 20 - 23
10 - 12 20 - 23
Night reduction heat circ.
Weekly program
Day by day
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Night reduction heat circ.
Weekly program
Block
Decrease
Sunday 22:00
Increase
Friday 14:00
Decrease
-------- 00:00
Increase
-------- 00:00
Holiday period
3
days
Holiday
When holiday is enabled, hot water production is stopped.
Temporary extra hot water and the weekly program for extra
hot water are stopped. The heat pump only operates in the
lower tank.
Содержание CTC EcoLogic Family series
Страница 2: ......
Страница 3: ...162 105 48 3 2016 04 08 Installation and Maintenance Manual CTC EcoLogic Pro Family...
Страница 67: ...67 CTC EcoLogic Pro Family For the property owner...
Страница 120: ...120 CTC EcoLogic Pro Family For the installer 11 Wiring diagram...
Страница 121: ...121 CTC EcoLogic Pro Family For the installer...
Страница 127: ......
Страница 128: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 105 48 3 2016 04 08...