52
CTC EcoLogic Pro/Family
For the property owner
4.5.3.6 Def. Solar Panels*
Solar panels (G30,B30, B31)
No (Yes/No)
Specify whether the circulation pump (G30) and sensors
(B30 and B31) are connected to the system.
Type
DHW only
Specify whether the solar energy should be supplied:
• to the hot water tank only
• to the buffer tank only
• to the hot water and buffer tanks
• to the boiler only (applies to system 1 only). (If this
is selected, the solar panels will pre-heat the hot
water in the boiler.)
Vacuum
No (Yes/No)
Specify whether the solar panels are vacuum or l at solar
panels.
Bore hole recharge (Y31, G31)
No (Yes/No)
There is an option of recharging the bore hole using
energy from the solar panels when the ordinary heating
and domestic hot water needs have been met.
4.5.3.7 Def. Pool*
Pool can be dei ned for systems 4, 5 and 6 only.
Pool (G50, G51, B50)
No (Yes/No)
Select whether circulation pumps (G51) and (G51) and
the sensors (B50) have been connected to the system.
4.5.3.8 Def. cooling*
Cooling (B3, B13, Y3, G3)
No (Yes/No)
Select whether the circulation pump (G3), mixing valve
(Y3) and sensors (B3 and B13) have been connected to
the system.
*Applies to the CTC EcoLogic PRO only.
Def. Solar Panels
Solar panels (G30, B30, B31)
No
Type
DHW only
Vacuum No
Drill hole recharge (Y31, G31)
No
Содержание CTC EcoLogic Family series
Страница 2: ......
Страница 3: ...162 105 48 3 2016 04 08 Installation and Maintenance Manual CTC EcoLogic Pro Family...
Страница 67: ...67 CTC EcoLogic Pro Family For the property owner...
Страница 120: ...120 CTC EcoLogic Pro Family For the installer 11 Wiring diagram...
Страница 121: ...121 CTC EcoLogic Pro Family For the installer...
Страница 127: ......
Страница 128: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 105 48 3 2016 04 08...