65
CTC EcoLogic Pro/Family
For the property owner
!
NOTE! Only an authorised service engineer is allowed to log in to the Factory set-
tings coded option. Severe operational problems and faults may occur affecting
the product if values are amended without authorisation. Note that in such cases
the warranty terms do not apply.
Test DHW circ/Solar/Pool*
The following pumps/valves are function tested from this
menu:
DHW circulation pump (G40)
On (On/Off)
Switches the circulation pump on and off.
Circulation pump solar (G30)
0 (0 to 100)
Tests the circulation pump to to full speed (rpm).
Heat exchanger pump solar (G32)
0 (0 to 100%)
Tests the solar heat exchanger pump up to full speed
(rpm).
Diverting valve solar (Y30)
DHW (DHW/Heating)
Tests the two modes on the valve: l ow to hot water
tank or buffer tank.
Solar charge borehole (Y31, G31)
Off (On/Off)
Tests the diverting valve (Y31) and solar heat exchanger
pump (G31).
Pool pumps (G50, G51)
Off (On/Off)
Tests the pool pumps and valve (G50, G51).
4.5.4.2 Alarm log Heat pumps
Here you can read information about the latest alarms
from the heat pump that sounded the alarm. The latest
alarm is displayed at the top and the four latest alarms
are shown under
Stored alarms.
An alarm which reoccurs within an hour is ignored so
as not to i ll up the log. If all the alarms are the same,
this can indicate that there is an intermittent fault, e.g. a
loose contact.
4.5.4.3 Factory settings Coded
This menu is intended to set the manufacturer’s
operational and alarm limits. A 4-digit code must be
specii ed to be able to amend these limits. However,
you can also take a look without any code to see what
options feature in the menu.
Test DHW circulation/Solar/Pool
DHW circulation pump (G40)
On
Solar panel pump (G30)
0
Solar heat exchanger pump (G32)
0
Solar diverting valve (Y30)
DHW
Solar charge borehole (Y31/G31)
Off
Pool pumps and valve (G50/G51)
Off
Alarm log Heat pumps
Latest alarm:
Time
HP(b) LP(b) SH(K) I(A)
A5 Low brine fl ow
07:20 6/3 8.8
3.3
15.9
3.9
Stored alarms:
A5 Wrong phase order
10:30 1/3 27.9
8.6
-227 50.0
A5 Com error motor prot. 09:01 1/3 27.9
3.6
42.2
0.0
Factory settings Coded
Code
0 0 0 0
Compressor operation
Expansion valve
Log compressor stop
Manual register change
*Applies to the CTC EcoLogic PRO only.
Содержание CTC EcoLogic Family series
Страница 2: ......
Страница 3: ...162 105 48 3 2016 04 08 Installation and Maintenance Manual CTC EcoLogic Pro Family...
Страница 67: ...67 CTC EcoLogic Pro Family For the property owner...
Страница 120: ...120 CTC EcoLogic Pro Family For the installer 11 Wiring diagram...
Страница 121: ...121 CTC EcoLogic Pro Family For the installer...
Страница 127: ......
Страница 128: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 105 48 3 2016 04 08...