Technical data
Proline Promag L 400 HART
124
Hauser
Nominal
diameter
Recommended
flow
Factory settings
min./max. full scale value
(v
~
0.3/10 m/s
Full scale value current
output
(v
~
2.5 m/s)
Pulse value
(
~
2 pulse/s)
Low flow cut off
(v
~
0.04 m/s)
[in]
[mm]
[gal/min]
[gal/min]
[gal]
[gal/min]
–
125
60 to 1
950
450
5
7
6
150
90 to 2
650
600
5
12
8
200
155 to 4
850
1
200
10
15
10
250
250 to 7
500
1
500
15
30
12
300
350 to 10
600
2
400
25
45
14
350
500 to 15
000
3
600
30
60
15
375
600 to 19
000
4
800
50
60
16
400
600 to 19
000
4
800
50
60
18
450
800 to 24
000
6
000
50
90
20
500
1
000 to 30
000
7
500
75
120
24
600
1
400 to 44
000
10
500
100
180
28
700
1
900 to 60
000
13
500
125
210
30
750
2
150 to 67
000
16
500
150
270
32
800
2
450 to 80
000
19
500
200
300
36
900
3
100 to 100
000
24
000
225
360
40
1
000
3
800 to 125
000
30
000
250
480
42
–
4
200 to 135
000
33
000
250
600
48
1
200
5
500 to 175
000
42
000
400
600
54
–
9 to 300 Mgal/day
75 Mgal/day
0.0005 Mgal
1.3 Mgal/day
–
1
400
10 to 340 Mgal/day
85 Mgal/day
0.0005 Mgal
1.3 Mgal/day
60
–
12 to 380 Mgal/day
95 Mgal/day
0.0005 Mgal
1.3 Mgal/day
–
1
600
13 to 450 Mgal/day
110 Mgal/day
0.0008 Mgal
1.7 Mgal/day
66
–
14 to 500 Mgal/day
120 Mgal/day
0.0008 Mgal
2.2 Mgal/day
72
1
800
16 to 570 Mgal/day
140 Mgal/day
0.0008 Mgal
2.6 Mgal/day
78
–
18 to 650 Mgal/day
175 Mgal/day
0.0010 Mgal
3.0 Mgal/day
–
2
000
20 to 700 Mgal/day
175 Mgal/day
0.0010 Mgal
2.9 Mgal/day
84
–
24 to 800 Mgal/day
190 Mgal/day
0.0011 Mgal
3.2 Mgal/day
–
2
200
26 to 870 Mgal/day
210 Mgal/day
0.0012 Mgal
3.4 Mgal/day
90
–
27 to 910 Mgal/day
220 Mgal/day
0.0013 Mgal
3.6 Mgal/day
–
2
400
31 to 1
030 Mgal/day
245 Mgal/day
0.0014 Mgal
4.1 Mgal/day
Recommended measuring range
Operable flow range
Over 1000 : 1