Incoming acceptance and product identification
Proline Promag L 400 HART
14
Hauser
4.2.2
Sensor nameplate
i
Patents
i
Material:
Tm:
Ext. ord. cd.:
Order Code:
Ser.No.:
Date:
2
1
3
4
5
6
7
8
9
10
11
13
12
14
15
A0017186
å
4
Example of sensor nameplate
1
Name of the sensor
2
Manufacturing location
3
Order code
4
Serial number (Ser. no.)
5
Extended order code (Ext. ord. cd.)
6
Nominal diameter of the sensor
7
Test pressure of the sensor
8
Medium temperature range
9
Material of lining and electrodes
10
Degree of protection: e.g. IP, NEMA
11
Permitted ambient temperature (T
a
)
12
2-D matrix code
13
CE mark, C-Tick
14
Flow direction
15
Manufacturing date: year-month
Order code
The measuring device is reordered using the order code.
Extended order code
• The device type (product root) and basic specifications (mandatory features) are always listed.
• Of the optional specifications (optional features), only the safety and approval-related
specifications are listed (e.g. LA). If other optional specifications are also ordered, these are
indicated collectively using the # placeholder symbol (e.g. #LA#).
• If the ordered optional specifications do not include any safety and approval-related
specifications, they are indicated by the
+
placeholder symbol (e.g. XXXXXX-ABCDE
+
).