Operating Instructions

Proline Promag L 400

HART

Electromagnetic flow measuring system

BA01062D/06/EN/01.12
71183770

Valid as of version
01.00.zz (Device firmware)

Содержание Proline Promag L 400 HART

Страница 1: ...Operating Instructions Proline Promag L 400 HART Electromagnetic flow measuring system BA01062D 06 EN 01 12 71183770 Valid as of version 01 00 zz Device firmware...

Страница 2: ...er to individuals or the facility read the Basic safety instructions section carefully as well as all other safety instructions in the document that are specific to working procedures The manufacturer...

Страница 3: ...using 28 6 3 Post installation check 30 7 Electrical connection 31 7 1 Connection conditions 31 7 1 1 Required tools 31 7 1 2 Requirements for connecting cable 31 7 1 3 Terminal assignment 33 7 1 4 Pr...

Страница 4: ...ss conditions 101 11 6 Performing a totalizer reset 101 11 7 Showing data logging 102 12 Diagnostics and troubleshooting 104 12 1 General troubleshooting 104 12 2 Diagnostic information on local displ...

Страница 5: ...symbol contains information on procedures and other facts which do not result in personal injury 1 2 2 Electrical symbols Symbol Meaning A0011197 Direct current A terminal to which DC voltage is appl...

Страница 6: ...o page Refers to the corresponding page number A0011196 Reference to graphic Refers to the corresponding graphic number and page number Series of steps Result of a sequence of actions A0013562 Help in...

Страница 7: ...can be ordered for the device Brief Operating Instructions Guide that takes you quickly to the 1st measured value The Brief Operating Instructions contain all the essential information from incoming...

Страница 8: ...eration time Only use the measuring device in full compliance with the data on the nameplate and the general conditions listed in the Operating Instructions and supplementary documentation Based on th...

Страница 9: ...sure continued operational safety and reliability Carry out repairs on the device only if they are expressly permitted Observe federal national regulations pertaining to repair of an electrical device...

Страница 10: ...5 6 7 8 1 E S C 3 A0017218 1 Important components of the compact version 1 Display module 2 Electronics cover 3 HistoROM DAT plug in memory 4 Main electronics module 5 Terminals screw terminals some...

Страница 11: ...dule 7 Terminals screw terminals some available as plug in terminals 8 Sensor housing cover 9 Sensor connection module screw terminals 10 Sensor connection housing 11 Sensor remote version 3 2 Registe...

Страница 12: ...rder code on the delivery note 1 identical to the order code on the product sticker 2 A0013695 A0015502 A0013698 Are the goods undamaged A0015502 A0013699 Do the nameplate data match the ordering info...

Страница 13: ...cumentation on the device 7 and Supplementary device dependent documentation 7 sections The W M Device Viewer Enter the serial number from the nameplate www endress com deviceviewer 4 2 1 Transmitter...

Страница 14: ...g IP NEMA 11 Permitted ambient temperature Ta 12 2 D matrix code 13 CE mark C Tick 14 Flow direction 15 Manufacturing date year month Order code The measuring device is reordered using the order code...

Страница 15: ...WARNING This symbol alerts you to a dangerous situation Failure to avoid this situation can result in serious or fatal injury A0011194 Reference to documentation Refers to the corresponding device do...

Страница 16: ...g or slipping Observe the weight specified on the packaging stick on label Observe the transport instructions on the stick on label on the electronics compartment cover A0015606 Observe the following...

Страница 17: ...Packaging Wood crate treated in accordance with ISPM 15 standard which is confirmed by the affixed IPPC logo or Carton in accordance with European Packaging Directive 94 62EC recyclability is confirme...

Страница 18: ...of gas bubbles in the measuring tube avoid the following mounting locations in the pipe Highest point of a pipeline Directly upstream of a free pipe outlet in a down pipe Installation in down pipes I...

Страница 19: ...d bearing strength NOTICE Very heavy Risk of damaging the metal casing and the internal magnetic coils Do not support the weight of the sensor on the metal casing A0016276 Orientation The direction of...

Страница 20: ...a partially filled or empty measuring tube A A 1 2 3 2 A0016260 6 Horizontal orientation 1 EPD electrode for empty pipe detection 2 Measuring electrodes for signal detection 3 Reference electrode for...

Страница 21: ...a shady location Avoid direct sunlight particularly in warm climatic regions Avoid direct exposure to weather conditions System pressure Never install the sensor on the pump suction side in order to a...

Страница 22: ...sure loss as a function of flow velocity downstream from the reduction and the d D ratio 100 10 0 5 d D mbar 0 6 0 7 0 8 0 9 1 m s 2 m s 3 m s 4 m s 5 m s 6 m s 7 m s 8 m s 1 D d max 8 A0016359 6 1 3...

Страница 23: ...e between the pipe flanges in a way that it is centered in the measurement section 3 If using ground disks comply with the Installation Instructions provided 4 Observe required screw tightening torque...

Страница 24: ...0 16 8 M16 10 22 80 PN 10 16 8 M16 15 30 100 PN 10 16 8 M16 20 42 125 PN 10 16 8 M16 30 55 150 PN 10 16 8 M20 50 90 200 PN 10 8 M20 65 130 250 PN 10 12 M20 50 90 300 PN 10 12 M20 55 100 350 PN 6 12 M2...

Страница 25: ...40 29 80 3 4 5 8 25 18 65 48 100 4 8 5 8 20 15 44 32 150 6 8 45 33 90 66 200 8 8 65 48 125 92 250 10 12 7 8 55 41 100 74 300 12 12 7 8 68 56 115 85 350 14 12 1 135 100 158 117 400 16 16 1 128 94 150 1...

Страница 26: ...627 1000 24 M30 634 1200 32 M30 727 Screw tightening torques for AS 4087 PN 16 Nominal diameter Threaded fasteners Max screw tightening torque Nm mm mm Hard rubber Polyurethane PTFE 350 12 M24 203 37...

Страница 27: ...n be mounted in the following ways Wall mounting Pipe mounting Wall mounting 149 5 85 210 5 8 29 5 8 0 23 mm in 18 0 71 14 0 55 5 8 0 23 A0017138 1 Drill the holes 2 Screw in the securing screws sligh...

Страница 28: ...er housing To provide easier access to the display module in the compact device version the transmitter housing can be turned Tightening torques for plastic housing Housing cover fixing screw Max 1 3...

Страница 29: ...ain electronics module 6 Remove the main electronics module along with the electronics cover 7 Loosen the fixing screws of the transmitter housing 8 Lift the transmitter housing 9 Turn the housing to...

Страница 30: ...temperature range Measuring range q Has the correct orientation for the sensor been selected According to sensor type According to medium temperature According to medium properties outgassing with en...

Страница 31: ...nge ambient temperature 20 K Power supply cable Standard installation cable is sufficient Signal cable Current output For 0 20 mA and 4 20 mA standard installation cable is sufficient For 4 20 mA HART...

Страница 32: ...Cable shield 7 Outer jacket Reinforced connecting cable Use in the following situations When laying the cable directly in the ground Where there is a risk of damage from rodents Operation in zones of...

Страница 33: ...e for Power supply Terminal numbers 1 L L 2 L N Option A AC 100 to 230 V Option B AC DC 24 V Signal transmission Order code for Output input Terminal numbers Output 1 Output 2 Output 3 Input 4 26 27 2...

Страница 34: ...remote version a Transmitter main electronics module with terminals b Sensor connection module c Electrode cable d Coil current cable n c Not connected insulated cable shields Terminal No and cable c...

Страница 35: ...ules Transmitter Electrode cable Coil current cable A B GND 80 3 15 50 1 97 17 0 67 8 0 31 100 3 94 mm inch 1 2 1 2 1 2 2 A0017404 A B 90 3 54 70 2 76 50 1 97 10 0 39 8 0 31 mm inch 1 A0017405 A Termi...

Страница 36: ...the transmitter PH 2 4 x 10 0 4 mm in 20 2122 23 24 2526 27 1 2 L L L N A0017268 1 Loosen the 4 fixing screws on the housing cover 2 Open the housing cover 3 Push the cable through the cable entry To...

Страница 37: ...ct the cable in accordance with the terminal assignment 34 6 Tighten the cable strain relief as per the tightening torque specifications 36 7 Firmly tighten the cable glands 8 WARNING Housing degree o...

Страница 38: ...fluid and sensor have the same electrical potential Pay attention to internal grounding concepts in the company Pay attention to the pipe material or grounding Connection examples for standard situati...

Страница 39: ...e transmitter Plastic pipe or pipe with insulating liner This connection method also applies in situations where The customary potential equalization is not used Equalizing currents are present A00163...

Страница 40: ...round terminal in the example always refers to the sensor and not to the transmitter 7 3 Ensuring the degree of protection The measuring device fulfills all the requirements for the IP66 67 degree of...

Страница 41: ...n with water trap 40 q Only for remote version is the sensor connected to the right transmitter Check the serial number on the nameplate of the sensor and transmitter q Does the supply voltage match t...

Страница 42: ...8 1 Overview of operation options 1 2 3 4 5 SC A0015607 1 Local operation via display module 2 Computer with Web browser e g Internet Explorer or with operating tool e g FieldCare AMS Device Manager S...

Страница 43: ...tput n Operating menu for experts Language Display operat Access status display Locking status Operation Setup Wizard 1 Parameter 1 Wizard 2 Parameter 2 Wizard n Parameter n Advanced setup Enter acces...

Страница 44: ...ed Device information submenu Contains information for identifying the device Measured values submenu Contains all current measured values Data logging submenu order option Storage and visualization o...

Страница 45: ...l display at the top right Status signals 106 Diagnostic behavior 107 Locking Communication Locking Symbol Meaning A0013963 Device locked The measuring device is hardware locked 96 Communication Symbo...

Страница 46: ...an one channel is present for the same measured variable type e g Totalizer 1 to 3 Diagnostic behavior The diagnostic behavior pertains to a diagnostic event that is relevant to the displayed measured...

Страница 47: ...t is present the diagnostic behavior and status signal In the wizard If a diagnostic event is present the diagnostic behavior and status signal For information on the diagnostic behavior and status si...

Страница 48: ...eaning A0013978 Switches to the previous parameter A0013976 Confirms the parameter value and switches to the next parameter A0013977 Opens the editing view of the parameter 8 3 3 Editing view Numeric...

Страница 49: ...from A to Z Aa1 A0013981 Toggle Between upper case and lower case letters For entering numbers For entering special characters A0013985 Confirms selection A0013987 Switches to the selection of the cor...

Страница 50: ...f the parameter With a Wizard Opens the editing view of the parameter With a text and numeric editor Pressing the key briefly Opens the selected group Carries out the selected action Pressing the key...

Страница 51: ...splay 1 Press F for 2 s The context menu opens XXXXXXXXXX l h 20 50 Setup Simulation A0017421 EN 2 Press S O simultaneously The context menu is closed and the operational display appears Calling up th...

Страница 52: ...8 1 0098 1 0098 1 XXXX XXX X X 10 50 2800 Hz mA Display operat Display operat Setup Main menu English Main menu Format display Display Contrast display Display intervall 1 value max Setup Access stat...

Страница 53: ...eter Totalizer 1 If a different channel is jumped to Enter the direct access code with the corresponding channel number Example Input of 0914 2 Parameter Totalizer 2 For the direct access codes of the...

Страница 54: ...mple Changing the parameter 20 mA value to 20 l h 3 4 0 2 9 5 6 8 7 l h 2x 20 000 l h 0 000 l h 100 000 l h 0 000 l h 100 000 3 4 0 1 2 9 5 6 8 7 l h 100 000 1 3 4 0 1 2 9 5 6 8 7 l h 0 3 4 0 1 2 9 5...

Страница 55: ...the user is currently logged on is indicated by the Access status display parameter Navigation path Display operation Access status display 8 3 11 Disabling write protection via access code If the sym...

Страница 56: ...2 Prerequisites Hardware Connecting cable Standard Ethernet cable with RJ45 connector Computer RJ45 interface Measuring device Web server must be enabled factory setting ON For information on enablin...

Страница 57: ...n the computer 2 Enter the IP address of the Web server in the address line of the Web browser 192 168 1 212 The login page appears Device tag Webserv language English Ent access code Access stat tool...

Страница 58: ...pending listed in order of priority Data management Data exchange between PC and measuring device in XML format Upload the configuration from the device Save the configuration to the device Network c...

Страница 59: ...ty Switch the Web server on and off Off On On Enabling the Web server If the Web server is disabled it can only be re enabled with the Web server functionality parameter via the following operating op...

Страница 60: ...PLC 2 Field Communicator 475 3 Computer with operating tool e g FieldCare AMS Device Manager SIMATIC PDM 4 Commubox FXA195 USB 5 Field Xpert SFX100 6 VIATOR Bluetooth modem with connecting cable 7 Tr...

Страница 61: ...ading and saving device data upload download Documentation of the measuring point Visualization of the measured value memory line recorder and event logbook For details see Operating Instructions BA00...

Страница 62: ...avigation area with operating menu structure Working area 8 5 4 AMS Device Manager Function scope Program from Emerson Process Management for operating and configuring measuring devices via HART proto...

Страница 63: ...s Endress Hauser 63 8 5 6 Field Communicator 475 Function scope Industrial handheld terminal from Emerson Process Management for remote configuration and measured value display via HART protocol Sourc...

Страница 64: ...s a list of the suitable device description file for each individual operating tool with source Operating tool via HART protocol Sources for obtaining device descriptions Field Xpert SFX100 Use update...

Страница 65: ...tput Output Assign TV Expert Communication HART output Output Assign QV The following measured variables can be assigned to the dynamic variables Measured variables for PV primary dynamic variable Vol...

Страница 66: ...the local display switches automatically from the startup display to the operational display If nothing appears on the local display or a diagnostic message is displayed refer to the section on Diagn...

Страница 67: ...Language A0017444 EN 20 Illustrated using the example of the local display Overview of the wizards in the Setup menu Setup Status input 67 Current output 69 Pulse frequency switch output 1 70 Pulse fr...

Страница 68: ...ption Parameter Description Selection User entry Factory setting Assign status input Select the function for the status input Off Reset totalizer 1 Reset totalizer 2 Reset totalizer 3 Reset all totali...

Страница 69: ...ow Conductivity Volume flow unit 4 20 mA NAMUR 4 20 mA US 4 20 mA Fixed current 0 4 mA value 20 mA value Failure mode Defined value Min Failure current End of wizard Off Mass flow unit Conductiv unit...

Страница 70: ...lect the current range for the process value output and for the upper and lower level for signal on alarm 4 to 20 mA NAMUR 4 to 20 mA US 4 to 20 mA 0 to 20 mA Fixed current Country dependent 4 to 20 m...

Страница 71: ...menu Pulse operating mode Parameter overview with brief description for pulse output Parameter Description Selection User entry Factory setting Operating mode Specify the output as a pulse frequency...

Страница 72: ...cc Fixed density Enter the fixed value for the density Floating point number Country dependent 1 kg l 1 g cc Pulse value Enter the measured value for the pulse output Depends on the process variable...

Страница 73: ...eq value Conductivity Conductiv unit Val at max freq Failure mode Failure freq Defined value Actual value 0 Hz A0017436 EN 24 Pulse frequency switch output 1 2 wizard in the Setup menu Frequency opera...

Страница 74: ...eter Density unit Select the unit for density Result The selected unit applies for Fixed density Unit choose list Country dependent kg l g cc Fixed density Enter the fixed value for the density Floati...

Страница 75: ...he wizard for the switch output End of wizard Operating mode Switch Switch out funct Diag behavior Off On Assign diag beh Alarm Alarm or warning Warning Invert outp sig A0017439 EN 25 Pulse frequency...

Страница 76: ...t A0017440 EN 26 Pulse frequency switch output 1 2 wizard in the Setup menu Switch operating mode Part 2 Parameter overview with brief description for switch output Parameter Description Selection Use...

Страница 77: ...equency output Switching output Simulation process variable Unit choose list S m Mass flow unit Select the unit for mass flow Result The selected unit applies for Outputs Low flow cut off Simulation p...

Страница 78: ...Format display Value 1 display 0 bargraph value 1 100 bargraph value 1 Value 2 display Value 3 display 0 bargraph value 3 100 bargraph value 3 Value 4 display End of wizard A0013797 EN 27 Display wiz...

Страница 79: ...output 1 None Value 3 display Select the measured value that is shown on the local display None Volume flow Conductivity Mass flow Totalizer 1 Totalizer 2 Totalizer 3 Current output 1 None 0 bargraph...

Страница 80: ...ode output 2 Mode output 1 Rev flow comp A0017459 EN 28 Output conditioning wizard in the Setup menu Reverse flow option only for pulse and frequency output Parameter overview with brief description P...

Страница 81: ...verse flow Reverse flow only for pulse and frequency output Reverse flow compensation Forward flow 10 4 6 Configuring the low flow cut off The Low flow cut off wizard guides you systematically through...

Страница 82: ...alue Enter the on value for low flow cutoff Positive floating point number 0 Switch off value Enter the off value for low flow cutoff 0 to 100 50 Pressure shock suppression Enter the time interval for...

Страница 83: ...ncel Empty pipe adj Progress Full pipe adjust Ok Busy Not ok On Switch point EPD Off A0017210 EN 30 Empty pipe detection wizard in the Setup menu Parameter overview with brief description Parameter De...

Страница 84: ...ne Promag L 400 HART 84 Endress Hauser Response time empty pipe detection Enter the time interval until the diagnostic message S862 Partially Filled Pipe is displayed for an empty or partially filled...

Страница 85: ...XXXXXX XXXXXXXXX XXXXXXXXX mA Display operat Setup Diagnostic Display operat Setup Main menu English Main menu Status input Setup Setup Advanced setup Ent access code Advanced setup Def access code De...

Страница 86: ...r overview with brief description Parameter Prerequisite Description User entry Factory setting Device tag The following option is selected in the Header parameter Device tag Enter the name for the me...

Страница 87: ...ation process variable Unit choose list mS cm Mass flow unit Select the unit for mass flow Result The selected unit applies for Outputs Low flow cut off Simulation process variable Unit choose list Co...

Страница 88: ...configured in the Electrode cleaning circuit ECC submenu Navigation path Setup menu Advanced setup Electrode cleaning circuit The wizard only appears if the device was ordered with an electrode cleani...

Страница 89: ...gative depending on the electrode material 10 5 5 Configuring the totalizer You can configure each totalizer in the three submenus Totalizer 1 3 Navigation path Setup menu Advanced setup Totalizer 1 S...

Страница 90: ...able parameter Volume flow Mass flow Select totalizer calculation mode Net flow total Forward flow total Reverse flow total Net flow total Failure mode One of the following options is selected in the...

Страница 91: ...78 100 bargraph value 1 78 Decimal places 1 Value 2 display 78 Decimal places 2 Value 3 display 78 0 bargraph value 3 78 100 bargraph value 3 78 Decimal places 3 Value 4 display 78 Decimal places 4 Di...

Страница 92: ...fluctuations in the measured value caused by process conditions 0 to 999 s 0 s Header Select header contents on local display Device tag Free text Device tag Header text The Free text option is select...

Страница 93: ...ce alarm Parameter overview with brief description Parameters Prerequisite Description Selection User entry Factory setting Assign simulation process variable Select a process variable for the simulat...

Страница 94: ...Set and switch off pulse output simulation Off Fixed value Down count val If the Fixed value option is selected the Pulse width parameter defines the pulse width of the pulses output 72 Off Pulse valu...

Страница 95: ...ain if a key is not pressed for 10 minutes in the navigation and editing view The device locks the write protected parameters automatically after 60 s if the user skips back to the operational display...

Страница 96: ...de this allows write access to the entire operating menu other than the Contrast display parameter to be locked The parameter values are now read only and cannot be edited any more exception Contrast...

Страница 97: ...meter 98 On the local display the symbol disappears from in front of the parameters in the header of the operational display and in the navigation view 3 WARNING Excessive tightening torque applied to...

Страница 98: ...due to internal device processing e g data upload download reset Once the internal processing has been completed the parameters can be changed once again 11 2 Adjusting the operating language Informa...

Страница 99: ...1 Totalizer overflow 1 Totalizer value 2 Totalizer overflow 2 Totalizer value 3 Totalizer overflow 3 Parameter overview with brief description Parameters Prerequisite Description Display Totalizer va...

Страница 100: ...the current measured values for every output Navigation path Diagnostics menu Measured values Output values The parameters displayed depend on The selected device order 33 The set operating mode of t...

Страница 101: ...ters with various options for resetting the three totalizers are available Control totalizer 1 3 Reset all totalizers Navigation path Display operat menu Operation Function scope of the Control totali...

Страница 102: ...led order option so that the Data logging submenu appears This contains all parameters for the measured value history Navigation path Diagnostics menu Data logging Function scope A total of 1000 measu...

Страница 103: ...g channel Off Volume flow Conductivity Mass flow Electronics temperature Current output 1 Off Logging interval Define the logging interval tlog for data logging This value defines the time interval be...

Страница 104: ...oil current cable and correct if necessary Local display is dark but signal output is within the valid range Display is set too bright or too dark Set the display brighter by simultaneously pressing O...

Страница 105: ...f the Internet protocol TCP IP 57 2 Check the network settings with the IT manager Not connecting to Web server Web server disabled Via the FieldCare operating tool check whether the Web server of the...

Страница 106: ...t have occurred can be called up in the Diagnostics menu Via parameters 113 Via submenus 114 Status signals The status signals provide information on the state and reliability of the device by categor...

Страница 107: ...nostic information The fault can be identified using the diagnostic information The short text helps you by providing information about the fault In addition the corresponding symbol for the diagnosti...

Страница 108: ...3 Service ID 4 Operation time of occurrence 5 Remedial measures The user is in the diagnostic message 1 Press O symbol The message for the remedial measures for the diagnostic event opens 2 Press S O...

Страница 109: ...diagnostic event Symbol Meaning A0017271 Failure A device error has occurred The measured value is no longer valid A0017278 Function check The device is in service mode e g during a simulation A00172...

Страница 110: ...re that problems can be rectified quickly On the home page Remedy information is displayed in a separate field below the diagnostics information In the Diagnostics menu Remedy information can be calle...

Страница 111: ...ered 12 6 Overview of diagnostic information Diagnostic number Short text Remedy information Status signal from the factory Diagnostic behavior from the factory Diagnostics for the sensor 043 Sensor s...

Страница 112: ...transfer F Alarm 411 Up download active Up download active please wait C Warning 431 Trim Carry out trim C Warning 437 Incompatible configuration 1 Restart device 2 Contact service F Alarm 438 Datase...

Страница 113: ...e 1 Check low flow cut off configuration S Logbook entry only 861 Process fluid Check process conditions F Alarm 862 Partly filled pipe 1 Check for gas in process 2 Adjust detection limits S Warning 8...

Страница 114: ...ents are pending the events with the highest priority are shown on the display Navigation path Diagnostics menu Diagnostic list Diagnostics Diagnose list Diagnostics 3 Diagnostics 2 F273 Main electron...

Страница 115: ...ering the event logbook Using the Filter options parameter you can define which category of event messages is displayed in the Events list submenu Navigation path Diagnostics menu Event logbook Filter...

Страница 116: ...t to its factory setting To delivery settings Every parameter for which a customized default setting was ordered is reset to that customized value all other parameters are reset to their factory setti...

Страница 117: ...found on the nameplate of the transmitter Promag 400 Order code Displays the device order code The order code can be found on the nameplate of the sensor and transmitter in the Order code field Charac...

Страница 118: ...ving the measuring device 1 Switch off the device 2 WARNING Danger to persons from process conditions Beware of hazardous process conditions such as pressure in the measuring device high temperatures...

Страница 119: ...Use only original Endress Hauser spare parts Carry out the repair according to the Installation Instructions Observe the applicable standards federal national regulations Ex documentation XA and cert...

Страница 120: ...ehold cleaners Methyl alcohol or isopropyl alcohol Mild soap solutions 14 1 2 Interior cleaning No interior cleaning is planned for the device 14 2 Measuring and test equipment Endress Hauser offers a...

Страница 121: ...as been ordered or delivered According to legal regulations Endress Hauser as an ISO certified company is required to follow certain procedures when handling returned products that are in contact with...

Страница 122: ...device versions are available Compact version the transmitter and sensor form a mechanical unit Remote version the transmitter and sensor are mounted separately from one another For information on the...

Страница 123: ...22500 6000 0 75 100 1000 40 850 to 28000 7000 1 125 42 950 to 30000 8000 1 125 1200 48 1250 to 40000 10000 1 5 150 54 1550 to 50000 13000 1 5 200 1400 1700 to 55000 14000 2 225 60 1950 to 60000 16000...

Страница 124: ...4000 225 360 40 1000 3800 to 125000 30000 250 480 42 4200 to 135000 33000 250 600 48 1200 5500 to 175000 42000 400 600 54 9 to 300 Mgal day 75 Mgal day 0 0005 Mgal 1 3 Mgal day 1400 10 to 340 Mgal day...

Страница 125: ...ng Adjustable 0 to 999 s Assignable measured variables Volume flow Conductivity Mass flow Pulse frequency switch output Function With the order code for Output Input option H output 2 can be set as a...

Страница 126: ...y pipe detection Low flow cut off Signal on alarm Depending on the interface failure information is displayed as follows Current output 4 20 mA Failure mode Selectable as per NAMUR recommendation NE 4...

Страница 127: ...browser Plain text display With information on cause and remedial measures Low flow cut off The switch points for low flow cut off are user selectable Galvanic isolation The following connections are...

Страница 128: ...ection 36 Potential equalization 38 Terminals Transmitter Supply voltage cable plug in screw terminals for wire cross sections 0 5 to 2 5 mm2 20 to 14 AWG Signal cable plug in screw terminals for wire...

Страница 129: ...of reading o f s of full scale value The outputs have the following base accuracy specifications Current output Accuracy Max 0 05 o f s or 5 A Pulse frequency output Accuracy Max 50 ppm o r Error lim...

Страница 130: ...covers are mounted these should never be removed before installing the measuring device Degree of protection Transmitter As standard IP66 67 type 4X enclosure When housing is open IP20 type 1 enclosu...

Страница 131: ...r Limit values for absolute pressure in mbar psi for fluid temperatures mm in 25 C 77 F 50 C 122 F 80 C 176 F 350 2400 14 90 Hard rubber 0 0 0 0 0 0 50 1200 2 48 Polyurethane 0 0 0 0 Liner PTFE Nomina...

Страница 132: ...50 PN 16 Table E 80 3 PN 16 14 PN 6 Class 150 14 PN 16 Table E 100 4 PN 16 16 PN 6 Class 150 16 PN 16 Table E 125 5 PN 16 21 5 PN 6 Class 150 PN 16 Table E 150 6 PN 16 25 5 PN 6 Class 150 25 5 PN 16 T...

Страница 133: ...ble E 2000 78 PN 10 2632 PN 6 1879 Class D 3115 PN 16 Table E 84 PN 10 PN 6 Class D 3757 PN 16 Table E 2200 PN 10 3424 PN 6 2514 Class D PN 16 Table E 90 PN 10 PN 6 Class D 4799 PN 16 Table E 2400 PN...

Страница 134: ...Transmitter remote version 1 15 kg 2 54 lb Sensor remote version Weight data Including the transmitter housing Excluding the connecting cable Excluding packaging material Weight in SI units Lap joint...

Страница 135: ...s D 383 PN 16 503 Table E 493 900 36 PN 10 393 PN 6 308 Class D 470 PN 16 702 Table E 690 1000 40 PN 10 468 PN 6 359 Class D 587 PN 16 759 Table E 761 1050 42 PN 10 PN 6 Class D 670 PN 16 Table E 1200...

Страница 136: ...00 28 Class D 587 750 30 Class D 701 800 32 Class D 845 900 36 Class D 1036 1000 40 Class D 1294 42 Class D 1477 1200 48 Class D 1987 54 Class D 1273 60 Class D 3515 1650 66 Class D 4699 1800 72 Class...

Страница 137: ...Table E PN 16 389 15 3 392 13 4 400 16 Class 150 389 15 3 392 13 4 450 18 PN 6 442 17 4 445 17 5 450 18 PN 10 493 19 4 445 17 5 450 18 Table E PN 16 440 17 3 443 17 4 450 18 Class 150 438 17 2 441 17...

Страница 138: ...203 47 4 1206 47 5 1200 48 PN 10 1199 47 2 1202 47 3 1200 48 Table E PN 16 1191 46 9 1194 47 0 1200 48 Class D 1195 47 0 1198 47 2 54 Class D 1345 53 8 1400 PN 6 1402 56 1 1400 PN 10 1394 5578 60 Clas...

Страница 139: ...ing DN 50 to 300 2 to 12 aluminum coated AlSi10Mg DN 350 to 2400 14 to 90 carbon steel with protective varnish Sensor connection housing Aluminum coating AlSi10Mg Sensor cable entries Order code for H...

Страница 140: ...1514 1 Accessories Weather protection cover Stainless steel 1 4301 Ground disks 1 4435 316L Alloy C 22 Fitted electrodes Measurement reference and empty pipe detection electrodes available as standard...

Страница 141: ...T handheld terminals Field Communicator 475 Field Xpert SFX100 Service interface CDI RJ45 Operation of the measuring device with the service interface CDI RJ45 via Web browser FieldCare operating tool...

Страница 142: ...Equipment General Requirements Pollution degree 2 Installation Category II CAN CSA C22 2 No 1010 1 92 Safety requirements for Electrical Equipment for Measurement and Control and Laboratory Use Pollu...

Страница 143: ...ppears if it has been additionally ordered Technical Information Section Application packages Language 66 Display operat 78 Language 66 Web server language 56 Access status display 55 Access status to...

Страница 144: ...1 Operating mode 71 Assign pulse output 71 Volume unit 71 Mass unit 72 Density unit 72 Fixed density 72 Pulse value 72 Pulse width 72 Failure mode 72 Invert output signal 72 Frequency output 73 Operat...

Страница 145: ...6 Assign limit 77 Assign flow direction check 77 Assign status 77 Volume flow unit 74 Conductivity unit 74 Mass flow unit 74 Unit 77 Switch on value 77 Switch off value 77 Switch on delay 77 Switch of...

Страница 146: ...low flow cut off 82 Off value low flow cutoff 82 Pressure shock suppression 82 Empty pipe detection 83 Empty pipe detection 83 New adjustment 83 Progress 83 Switch point empty pipe detection 83 Respo...

Страница 147: ...ime 89 ECC cleaning cycle 89 ECC polarity 89 Totalizer 1 to 3 89 Assign process variable 89 Unit 89 Totalizer operation mode 90 Failure mode 90 Display 91 Format display 78 Value 1 display 79 0 bargra...

Страница 148: ...Timestamp Operating time from restart Operating time 115 Diagnostics list 114 Diagnostics 1 to 5 114 Timestamp Event logbook 114 Filter options 115 Events list 115 Device info 116 Device tag 86 Seria...

Страница 149: ...9 Value status input 100 Output values 100 Output current 1 100 Measured current 1 101 Pulse output 1 to 2 101 Output frequency 1 to 2 101 Switch status 1 to 2 101 Data logging 102 Assign channel 1 4...

Страница 150: ...t 116 Expert 44 Direct access 0106 52 Locking status 0122 55 Access status display 0091 55 Access status tooling 0005 55 Enter access code 0003 System Define access code 95 Define access code 95 Confi...

Страница 151: ...c behavior 104 Alarm delay 0651 107 Assign behavior of diagnostic no 441 0657 112 Assign behavior of diagnostic no 442 0658 112 Assign behavior of diagnostic no 443 0659 112 Assign behavior of diagnos...

Страница 152: ...flow 1 to 3 0910 99 Input values 99 Value status input 1353 100 Output values 100 Output current 1 0361 100 Measured current 1 0366 101 Pulse output 1 to 2 0456 101 Output frequency 1 to 2 0471 101 Sw...

Страница 153: ...0 83 Switch point empty pipe detection 6562 83 Response time empty pipe detection 1859 84 New adjustment 6560 83 Progress 6571 83 Electrode cleaning circuit 88 Electrode cleaning circuit 6528 88 ECC d...

Страница 154: ...Zero point 6546 Input Status input 67 Assign status input 1352 68 Value status input 1353 100 Active level 1351 68 Response time status input 1354 68 Output Current output 1 69 Assign current output...

Страница 155: ...ut signal 0470 72 Frequency output 73 Operating mode 0469 73 Assign frequency output 0478 74 Minimum frequency value 0453 74 Maximum frequency value 0454 74 Measuring value at minimum frequency 0476 7...

Страница 156: ...de 0486 77 Switch status 0461 101 Invert output signal 0470 77 Communication HART output 64 Configuration 65 Burst mode 0208 65 Burst command 0207 65 HART address 0219 65 No of preambles 0217 65 HART...

Страница 157: ...rver 56 Web server language 7221 56 MAC address 7214 56 IP address 7209 56 Subnet mask 7211 56 Default gateway 7210 56 Web server functionality 7222 56 Application Reset all totalizers 2806 102 Totali...

Страница 158: ...Device tag 0011 86 Serial number 0009 117 Firmware version 0010 117 Device name 0013 117 Order code 0008 117 Extended order code 1 to 3 0023 0021 0022 117 ENP version 0012 117 IP address 7209 118 Sub...

Страница 159: ...3 Value process variable 1811 93 Simulation status input 1355 93 Value status input 1356 94 Simulation current output 1 0354 94 Value current output 1 0355 94 Frequency simulation 1 to 2 0472 94 Frequ...

Страница 160: ...planation 50 Opening 50 C Tick symbol 142 Current consumption 128 D Declaration of Conformity 9 Define access code 95 96 Degree of protection 40 130 Design Measuring device 10 Designated use 8 Device...

Страница 161: ...Fitted electrodes 140 Flow direction 19 Flow limit 131 Function check 66 Functions see Parameter Function scope AMS Device Manager 62 Field Communicator 63 Field Communicator 475 63 Field Xpert 61 SIM...

Страница 162: ...lements 50 107 Operating keys see Operating elements Operating menu Menus submenus 43 Structure 43 Submenus and user roles 44 Operating menu overview Operators and maintenance 143 Operating philosophy...

Страница 163: ...Signal on alarm 126 SIMATIC PDM 62 Function 62 Software release 64 Spare part 119 Spare parts 119 Standards and guidelines 142 Status area For operational display 45 In the navigation view 47 Status...

Страница 164: ...ated use Borderline cases 8 Incorrect use 8 User roles 44 V Version data for the device 64 Vibration resistance 130 Vibrations 21 W W M 119 120 W M Device Viewer 13 119 Weight Compact version 132 Sens...

Страница 165: ...__________________________________________ ______________________________________________________________________________________________________________ We hereby certify that this declaration is fil...

Страница 166: ...www endress com worldwide BA01062D 06 EN 01 12 71183770 EH COSIMA ProMoDo...

Отзывы: